AI3050S Sargas AEI Reader
8
March 25, 2018
Figure 7 - Sargas Network Settings
Please note that because the Sargas Railroad AEI RF Reader has a special railroad
interface, many of the configuration parameters shown in its browser pages have been
disabled.
4. QT50R Presence Radar
The QT50R presence radar should be mounted 30 inches above the top of the rail on the
same pole as the controller. The front of the radar should be facing the track and pointing up
at a 20 degree angle. In the back of the unit there is a set of 8 dipswitches. To open the back
of the unit insert the special tool into the holes and turn counter clockwise. See Figure 8.
The dipswitches should have the following settings:
Switch 1 down
Switch 2 down
Switch 3 up
Switch 4 down
Switch 5 up
Switch 6 down
Switch 7 down
Switch 8 up
The dipswitches should have been pre-set to the preceding positions prior to shipment.