![SOFTLINK Sigfox WS868-PLE-I Manual Download Page 22](http://html1.mh-extra.com/html/softlink/sigfox-ws868-ple-i/sigfox-ws868-ple-i_manual_1312443022.webp)
Value1
setting of initial value of the first port counter (index ”0”)
Value2
setting of initial value of the second port counter (index ”1”)
Send periode
setting of broadcasting period
Measure periode
setting of A/D measurement interval
The
”
Value1”
parameter is used for setting of the initial (or current) value of internal counter for registration of
gas-meter revolving. After this setting the initial value increases by one unit with each turn of gas-meter mechanical
counter.
The
”
Value2”
parameter is used for registration of tamper status. Current value of this variable (0/1) shows,
whether the tamper reed-contact is connected or released. Setting of this value has no practical meaning.
The
”
Send periode”
parameter is used for setting of broadcasting period of regular information messages. Value
of the period should be set in seconds. More detailed description of this parameter and its setting can be found in
paragraph
”
Commands for setting of timers”.
WARNING!
. Frequency of broadcasting in Sigfox network is under regulation. Each device working in Sigfox
network has assigned its service profile that enables only limited number of broadcasted messages per day. Exceeding
this limit can cause some restriction or sanction from the Sigfox service provider. When setting this parameter,
check whether the setting complies with a service contract, that is valid for configured device.
The
”
Measure periode”
parameter is used for setting of analog quantities (temperature, voltage..) measurement
interval in seconds. More detailed description of this variable and possibilities of its setting are explained in details
in paragraph
”
Commands for setting of timers”.
Setting of
”
Value1” and
”
Send periode”
variable can be performed by editing (rewriting) of current value
to required number and clicking to
”
Write” button. The process can be observed by flashing of green LED on
the converter and yellow LED on the module. After each writing of new values
”
WACO OptoConf” program
automatically re-read actual data from the module, so that if required values will display in the configuration
window at the end (after yellow LED on the module ceases flashing), the process was completed successfully.
In the
lower section of the table
there are current values of external and internal sensors (temperature, volt-
age...). There are following parameters:
Sens. Temperature
current sensor temperature (not applicable)
CPU Temperature
current processor temperature (read only)
Batt. voltage
current battery voltage (read only)
In the non-editable fields
”
Sens.
Temperature”
,
”
CPU Temperature”
and
”
Batt.
voltage”
there are
displayed current values of module sensor temperature (not used), processor temperature and battery voltage.
CPU temperature and battery voltage values are transmitted in each info-message (see description of information
message in section
”
Structure of WS868-PLE-I module data message”).
WS868-PLE-I
19