In the first row there are displayed following device specifications:
manufacturer type
(Device name),
hardware
version/revision
(HW version.revision) and
software version/revision
(SW vesion.revision). These specifica-
tions are factory set and cannot be changed.
In the second row there are values of module
system time
in common time format,
reset cause
of module
last reset and value of module
”Uptime”
.
The
”
Systime”
parameter value shows setting of module real time. System time is kept in the same format as
in computer operating systems, i.e. in seconds, starting from 1.1.1970 (
”
UNIX Epoch time”). In default status
(after battery switch-on) there is zero value in the counter and it increases by one every second. As setting of this
parameter is not required for any common application of the module, command for its setting is not included in
the set of configuration commands.
The
”
Uptime”
parameter value shows the time interval passed from the last device reset in seconds so that the
exact moment of the last module reset can be recognized by this parameter. The parameter cannot be changed by
user (
”
read only” type).
The
”
Reset cause”
parameter value gives an information about the last reset circumstances. Following reset codes
are relevant for this type of device:
-
”
0”
means
”
Cold start” (caused by user
”
RESET” command)
-
”
1”
means
”
Warm start” (based on
”
suspension” cause
-
”
2”
means
”
Watchdog reset” (reset by
”
watchdog“ system)
-
”
3”
means
”
Error reset” (incorrect instruction or inconsistent data)
-
”
4”
means
”
Power reset” (caused by low power voltage)
The parameter has
”
read only” character and it is used mainly for the diagnostics.
In the third row there is a value of module Sigfox
ID
, that is an
unique identifier of the device
in the Sigfox
global network. This ID is permanently assigned to the given module and cannot be changed.
In the fourth row there is a value of module Sigfox
”PAC” code
(Personal Authentication Code), that is an
unique identifier of
assigning
of the given device to
concrete customer
- service contractor. Initial PAC-code is
assigned to the module in factory and can be changed only with co-operation with Sigfox network provider (with
possible change of service contractor). Initial PAC-code is written in module configuration as an information for
user. Setting of this parameter has no influence on the module functionality. After possible change of service
contractor, the new contractor could decide to register change of PAC-code in the module configuration or not.
In next rows there are values of
current temperature
measured by sensor (temperature [1]),
current processor
temperature
(temperature [2]),
current humidity
measured by sensor (humidity[1]), and
current voltage of
internal battery
(voltage [1]). As the module is not equipped by temperature/humidity sensors, the ”temperature
[1]” and ”humidity[1]” values are random numbers with no practical meaning.
WS868-PLE-I