SOFTLINK Sigfox WS868-PLE-I Manual Download Page 21

3.6

Setting of parameters by using of optical

USB-IRDA” converter

All parameters that is necessary to set-up during common operation can be configured by optical interface. The
settings can be performed through the translucent casing without necessity to open the module’s cover. This is the
significant advantage especially if the module is already mounted to gas-meter and sealed by antifraud seal, because
it is not possible to remove cover without breaking seal.

Principles of the optical configuration, technique of connection to computer and working procedure with using of
the

WACO OptoConf”

program are explained in detail in the section

3.2

Configuration of the WS868-PLE-I

module with using of optical converter”.

Any changes in module’s settings can be performed in

Module configuration table

that opens by click on the

Read device” button in

WACO OptoConf” program window. View of configuration table is depicted in figure

16

.

Figure 16: The WS868-PLE-I module configuration table

In the

upper section of the table

there are

read only” type of parameters (factory settings) that refer to the

identification of the module and its components. There are following parameters:

Device name

device name by manufacturer

Device type

device type by manufacturer

Device subtype

device subtype by manufacturer

Serial No.

device serial number (as well MBUS-ID in M-Bus address)

HW Version

hardware version by manufacturer

HW Revision

hardware revision by manufacturer

SW Version

software version by manufacturer

SW Revision

software revision by manufacturer

Uptime

elapsed time from last reset in seconds

All the parameters (except

Uptime”) contain information about device identification, series and hardware/software

version and are intended only for manufacturer’s use.

In the

middle section of the table

there is a group of commonly used configurable parameters of the WS868-

PLE-I module. There are following parameters:

WS868-PLE-I

18

Summary of Contents for Sigfox WS868-PLE-I

Page 1: ...WIRELESS COMMUNICATION SYSTEM Sigfox WS868 WS868 PLE I Revision 1 0 SOFTLINK s r o Tomkova 409 278 01 Kralupy nad Vltavou Czech Republic Phone 420 315707111 e mail sales softlink cz www softlink cz...

Page 2: ...of WS868 PLE I module parameters by configuration cable 13 3 5 1 List of WS868 PLE I module configuration parameters and commands 13 3 5 2 Commands for saving of configuration parameters and reset 13...

Page 3: ...erter 6 7 Displaying of the optical converter in the Windows Device Manager 7 8 Displaying of WACO OptoConf configuration window 7 9 List of variables in the working window of WACO OptoConf program 7...

Page 4: ...network server to the application servers of authorized users through the unified data interface via public Internet 1 2 Module usage The WS868 PLE I module can be used for remote reading of Elster BK...

Page 5: ...ynchronous Transmission parameters 8 data bits 1 stop bit none parity Signal level TTL CMOS Optical configuration interface Transmission speed 115 200 Baud Optical interface specification IrPHY 1 4 st...

Page 6: ...e to computer Configuration can be performed by using of common USB port of the computer For the interconnection with a USB port of computer it is necessary to use a manufacturer s original configurat...

Page 7: ...nal setting for serial line communication PuTTY software runs after clicking on the downloaded file putty exe There will open a window of the terminal communication see Figure 4 For switching the prog...

Page 8: ...ers HELP enter question mark or and press ENTER key when entering characters distinguish strictly the capital and small letters according to the documentation or HELP Do not enter other characters tha...

Page 9: ...ow 3 2 2 Connection of USB IRDA optical converter to computer Before starting of the WACO OptoConf program connect the USB IRDA converter to USB port of the computer When the converter is connected to...

Page 10: ...ystem communication systems can be found on the producer s WEB site NEP Page By clicking to Read device button the textbfconfiguration table with all the relevant parameters of the module is displayed...

Page 11: ...n between module and converter is reliable When working directly at the installation site always use a special holder that is designed for attaching of converter to the module Put the holder to the WS...

Page 12: ...s either bad position of the module long distance wrong orientation dirty cover obstacle in the beam or the module s battery was switched off NOTE WACO OptoConf program contains specific data and sett...

Page 13: ...ce see figure 13 left Figure 13 Displaying of the device without driver in Device Manager window By right clicking to USB Serial port open the context menu and choose Update driver software item Click...

Page 14: ...d Boot Options appears choose Disable Driver Sig nature Enforcement option in this window after launching the system install the driver according the above mentioned instructions Deactivation of the e...

Page 15: ...g to the above described procedure Deactivation of the enforcement of signed driver function of the Windows 10 operating system is functional only until the next restart of the system 3 4 3 Support of...

Page 16: ...M enable mode setup on startup ppm set Xtal ppm s sec set sending time in seconds m sec set measure time in seconds d n n th uplink message has downlink capability 0 no downlink i index value set init...

Page 17: ...broadcasting period The period is set in seconds and the module broadcasts its INFO messages spontaneously with this period Example of setting of broadcasting period to 1 hour 3600 seconds and corres...

Page 18: ...utput value counter value multiplier i index d value setting of divisor output value counter value divisor Important note The first input with index 0 that registers revolving of gas meter pivotal whe...

Page 19: ...initialization mode Mode setup Do not use Only for factory setting ppm enteering of XTAL correction constant Do not use Only for factory setting D number debug statement switch on Do not use Only for...

Page 20: ...t based on suspension cause 2 means Watchdog reset reset by watchdog system 3 means Error reset incorrect instruction or inconsistent data 4 means Power reset caused by low power voltage The parameter...

Page 21: ...nf program window View of configuration table is depicted in figure 16 Figure 16 The WS868 PLE I module configuration table In the upper section of the table there are read only type of parameters fac...

Page 22: ...ontract that is valid for configured device The Measure periode parameter is used for setting of analog quantities temperature voltage measurement interval in seconds More detailed description of this...

Page 23: ...7 Structure of module data messages The WS868 PLE I module is intended for reading of data from Elster gas meters of BK G series and broadcasting of measured data through the Sigfox RF network Maximu...

Page 24: ...capacity reduces frequency of broadcasting 4 2 The condition of modules on delivery Modules are delivered in standard cardboard boxes The modules are commonly delivered in fully operating status with...

Page 25: ...de of the module should be locked inside the gas meter lock connect module sealing protrusion with matching protrusion on the gas meter by sealing screw or sealing wire or other prescribed way and sea...

Page 26: ...as meter counter status and seal number Fill in the prescribed service documentation If possible arrange making of all appropriate changes in the database of the remote reading system immediately 4 8...

Page 27: ...y batteries used in the wacoSystem modules that have been carefully selected and properly tested In case of battery replacement by user the new battery parameters should meet same technical requiremen...

Page 28: ...ce these elements for the spare ones with proven functionality check correctness of module settings and perform the check of module overall functionality as described in paragraph 4 9 replace the modu...

Page 29: ...nfiguration options of WS868 PLE I RF modules designed for operation in Sigfox IoT network in868 MHz frequency band that are a part of the Softlink s wacoSystem product family More information about a...

Reviews: