edgeGate - Quick Startup Guide

18

© Softing Industrial Automation GmbH

4.3

Login

Log in with the respective login name and password.

The following standard user names and passwords are available:

Role

User name

Password

Administrator

administrator

administrator

IT administrator

itadmin

itadmin

Service or maintenance engineer

mfadmin

mfadmin

Note

We highly recommend changing the standard passwords to new secure passwords after you
logged in for the first time.

4.4

Completing Your Configuration

To complete your configuration, you need to configure:

Time settings

IT settings

Machine settings including symbol import

For detailed information see the online help in the web server application.

Summary of Contents for edgeGate

Page 1: ...edgeGate Quick Startup Guide Version EN 082020 1 72 Softing Industrial Automation GmbH...

Page 2: ...ime of printing of it and is passed on with the best of our knowledge The information in these instructions is in no event a basis for warranty claims or contractual agreements concerning the describe...

Page 3: ...tended Use 7 2 2 Scope ofDelivery 8 2 3 Safety Precautions Chapter 3 9 Hardware Installation 9 3 1 Mounting and Dismounting 11 3 2 Connecting the Power Supply 12 3 3 Connecting to the Network 13 3 4 P...

Page 4: ...Table of Contents Softing Industrial Automation GmbH 4 Chapter 5 19 LED Status Indicators Chapter 6 21 Technical Data Chapter 7 22 Declarations of Conformity...

Page 5: ...ully understood the safety requirements and working instructions in this guide 1 3 Typographic Conventions The following conventions are used throughout Softing customer documentation Keys buttons men...

Page 6: ...n providing you with helpful user hints 1 4 Document Feedback Softing likes to encourage you to provide feedback and comments to help us improve the documentation If you have a PDF copy of this docume...

Page 7: ...ork solutions and grow them over time Any other use is not intended Follow the instructions given in this guide to use edgeGate Note Faultless and safe operation of the product requires proper transpo...

Page 8: ...he product is unnecessary and not permitted The product must only be operated within the specified temperature range Do not expose to heat above this temperature range and keep away from open fire Sto...

Page 9: ...be reached easily Note Depending on the installation position the maximum ambient operating temperature may differ Refer to the Technical Data section for detailed information CAUTION Installation an...

Page 10: ...geGate down towards the rail until it slides into place over the lip of the locking bar Note Do not put stress on the device by bending or torsion Dismounting 1 Slide a screwdriver diagonally under th...

Page 11: ...re must have a cross section of 1 5 mm Wiring Diagram for Hardware V1 01 and Lower Pin Signal Description 4 L2 Redundant positive supply voltage 3 L Positive supply voltage 2 Functional Earth 1 GND Gr...

Page 12: ...bH 3 3 Connecting to the Network edgeGate is equipped with two 10 100 Base T Ethernet interface receptacle RJ45 The ports correspond to the IEEE 802 3 standard IT for connecting to the IT network uppe...

Page 13: ...2 1 Common Network If there is only one logical network than it is recommended to connect only the IT Ethernet interface with this network In this case the Ethernet interface of the machine side shoul...

Page 14: ...the range of the operating temperature of edgeGate The storage capacity of the micro SD card may not exceed 32 GB 1 Remove the card slot cover on the bottom of the device 2 Insert the micro SD card ca...

Page 15: ...vice confirms the reset procedure after about 20 30 seconds by simultaneous illumination of the red RUN ERR and SYS LEDs 5 Wait until the PWR and RUN LEDs light up continuously in green Then the gatew...

Page 16: ...n the common LAN is configured per default via DHCP Depending on the configuration of your local DHCP and DNS servers it is possible to reach the device by this host name in your network Starting with...

Page 17: ...host name is edgegate89ab 3 Open your browser and enter the address http hostname or https hostname 4 The login window appears 1 Connect the lower Ethernet socket MACHINE directly to a laptop 2 Set t...

Page 18: ...dministrator IT administrator itadmin itadmin Service or maintenance engineer mfadmin mfadmin Note We highly recommend changing the standard passwords to new secure passwords after you logged in for t...

Page 19: ...our LEDs on its front side PWR Power Supply permanently green if the 24 VDC power supply is OK RUN Running ERR Error SYS System The LEDs may be on permanently or flash in different colors and frequenc...

Page 20: ...e the consistency of the image is checked and the kernel is exchanged Flashing red while the firmware is replaced with the firmware image content During this time the device is not fully operational E...

Page 21: ...0 C 40 C 22 5 mm minimum distance Storage temperature 40 C 85 C Relative humidity 10 90 non condensing Altitude Must not exceed 2 000 m Location Indoor use only no direct sunlight Dimensions H x W x D...

Page 22: ...Part 6 4 generic standard emission for industrial environments EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 generic standard immunity for industrial environments Note To fulfill the EMC re...

Page 23: ...accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case th...

Page 24: ...Softing Industrial Automation GmbH Richard Reitzner Allee 6 85540 Haar Germany https industrial softing com 49 89 4 56 56 340 49 89 4 56 56 488 info automation softing com...

Reviews: