background image

Chapter 8 - CE Compliance

© Softing Industrial Automation GmbH

23

Summary of Contents for Data Flow commModule MBP

Page 1: ...Softing Industrial Automation GmbH commModule MBP Hardware Manual Version EN 022018 1 00...

Page 2: ...rations or improvements to these instructions without prior notice The actual design of products may deviate from the information contained in the instructions if technical alterations and product imp...

Page 3: ...e 9 3 5 Fault Disconnect Equipment 9 3 6 Simulate enable Chapter 4 10 Electrical specifications 10 4 1 Protocol select 10 4 2 Operating conditions 10 4 3 Port input and output Chapter 5 12 Environment...

Page 4: ...omation GmbH Table of Contents 4 20 7 5 Label 20 7 6 Maintenance and spare parts Chapter 8 21 CE Compliance 22 8 1 ATEX EC type examination certificate 27 8 2 IECEx Certificate of Conformity 35 8 3 De...

Page 5: ...rmware see the following document commScript PD Customization Guide 1 3 Conventions used The following conventions are used throughout Softing customer documentation CAUTION This symbol indicates a po...

Page 6: ...fe fieldbus Profibus PA and Foundation Fieldbus to the field device CAUTION The commModule MBP is certified for the use in hazardous areas when used in accordance with its specification and operating...

Page 7: ...TX Interface signal for HART RTS9_PB5 2 DO Low active RTS signal for HART RXD9_PB6 3 DI RX Interface signal for HART GPIO_PA4 4 GPIO For future use GPIO_PE6 5 GPIO AI For future use CTS9_PB4 6 DI Low...

Page 8: ...IO For future use GPIO_PC5 29 GPIO For future use GPIO_PC4 30 GPIO For future use EMLE 31 DBG Programming Interface TDI 32 DBG Programming interface GPIO_PD2 33 GPIO For future use RESET 34 DBG Progra...

Page 9: ...ing Only used for internal flash programming with Renesas Flash Programmer 11 FINEC Programming Interface 1 FINED Programming Interface 7 PC7 Programming Interface 10 RESET Programming Interface 13 GN...

Page 10: ...Vcc 3 2V 4 Parameter Symbol Min Max Unit Test Conditions DI input low voltage VIL Vcc x 0 2 V DI input high voltage VIH Vcc x 0 8 V DO output low voltage VOL 0 5 V IOL 1mA DO output high voltage V OH...

Page 11: ...internal series resistance 10 Ohms Io 1mA 6 2 6 05 6 3 V Fieldbus Physical Layer according to IEC 61158 2 type 3 voltage mode 31 25kBit s Rated current adjusted in software to In 10mA up to 26mA Powe...

Page 12: ...Max Note operating temperature C 40 80 storage temperature C 40 85 humidity rH 10 90 non condensing Operating conditions for use in hazardous environment Operating temperature is dependent on intrinsi...

Page 13: ...ecifications Softing Industrial Automation GmbH 13 5 3 Certifications ROHS The commModule MBP is ROHS compliant ATEX IECEx IECEx IBE 17 0038U Ex ia IIC Ga Ex ia Da IIIC IBExU17ATEX1135 U II 1G Ex ia I...

Page 14: ...ion GmbH 6 Mechanical specification The weight of a potted variant commModule MBP STD is approximately 15 gram The weight of the non potted variant commModule MBP STD_NOP is 8 gram 6 1 Module dimensio...

Page 15: ...print The PCB footprint dimensions may be modified based on user experience and or process capability Routing under the CommModule MBP Note The host PCB footprint must not contain any exposed copper u...

Page 16: ...nsic safety 1 Ensure there is no copper within 0 5mm of the marked Keep Out Area on the host PCB 2 Ensure a clearance of 2mm between signals on Pin 40 43 to all other pins 3 Ensure a clearance of 2mm...

Page 17: ...mmendations The following temperatures and times are recommended for variant commModule MBP STD_NOP Ramp up rate 3 C second max Maximum time maintained above 217 C 40 60 seconds Peak reflow temperatur...

Page 18: ...on compliance the warranty and manufacturer s liability do no longer apply It has to be ensured that only such equipment is installed which complies with the types of protection applicable to the rele...

Page 19: ...cal parameters of connected devices must match the values described in the technical section Local requirements for electrical equipment for use with hazardous location associated with explosive atmos...

Page 20: ...en these signals Clearance and creepage distance to all other signals with level of protection 30V according to table 5 in IEC 60079 0 7 5 Label The commModule MBP is marked with a label similar to th...

Page 21: ...ompliance Softing Industrial Automation GmbH 21 8 CE Compliance This device complies with the following EC directives EC directive 2014 30 EU EMC directive EC directive 2014 34 EU ATEX EC directive 20...

Page 22: ...commModule MBP Hardware Manual 22 Softing Industrial Automation GmbH 8 1 ATEX EC type examination certificate...

Page 23: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 23...

Page 24: ...commModule MBP Hardware Manual 24 Softing Industrial Automation GmbH...

Page 25: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 25...

Page 26: ...commModule MBP Hardware Manual 26 Softing Industrial Automation GmbH...

Page 27: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 27 8 2 IECEx Certificate of Conformity...

Page 28: ...commModule MBP Hardware Manual 28 Softing Industrial Automation GmbH...

Page 29: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 29...

Page 30: ...commModule MBP Hardware Manual 30 Softing Industrial Automation GmbH...

Page 31: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 31...

Page 32: ...commModule MBP Hardware Manual 32 Softing Industrial Automation GmbH...

Page 33: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 33...

Page 34: ...commModule MBP Hardware Manual 34 Softing Industrial Automation GmbH...

Page 35: ...Chapter 8 CE Compliance Softing Industrial Automation GmbH 35 8 3 Declaration of Conformity...

Page 36: ...Tel 49 89 45 656 340 Fax 49 89 45 656 488 info idn softing com Richard Reitzner Allee 6 85540 Haar Germany http industrial softing com Softing Industrial Automation GmbH...