background image

K-Scan PC User Manual                                                 文書番号:SFT-20070171 

 

Page  7 of 35

 

                         

  

・4

-

Log File View 

 

Log File View Setting 

 

Transfer Setting 

Show Transfer Setting Dialog. 

 

Language Setting 

Show Language Setting Dialog. 

-

10

 

 

Data Recording Setting  Show Data Recording Setting Dialog. 

 
[Available Screen] 

・4

-

Data Recording 

-

-

 

 

Throttle Setting 

Display Throttle Setting Dialog. 

-

11

 

 ECU 

Information 

Show 

ECU Information Dialog. 

-

12

 

 

VIN Setting 

Show VIN Setting Dialog. 

-

13

 

 

Unit 

Select a unit mode. 
SI: (Deg C, kPa ) 

USA: (Deg F, inHg) 

 

Help 

Help 

Display this document. 

 

 

About K-Scan 

Display About K-Scan Dialog. 

-

14

 

 

3-2 

Toolbar 

Following table shows the toolbar composition. 
And some buttons that are only available in particular screens. 

 

Group Icon 

Name 

Overview 

File 

 

 

Open Log File 

Show common dialog to load a log file. 

 

[Available Screen] 

・4

-

Log File View 

 

 

Save 

Show common dialog to save screen data. 

 
[Available Screen] 

・4

-

Data View 

・4

-

Diagnosis   

 

 

Print 

Show common dialog to print screen data 
or screen image. 

[Available Screen] 

・4

-

Data View Large 

・4

-

Data View 

・4

-

Graph View 

・4

-

Diagnosis  

・4

-

Log File View 

View 

 

Title View 

Move to Title View screen. 

 

 

 

Data View Large 

Move to Data View Large Screen. 

 

 

 

Data View 

Move to Data View Screen. 

 

 

 

Graph View 

Move to Graph View Screen. 

 

 

 

Active Test 

Move to Active Test Screen. 

 

 

 

Diagnosis 

Move to Diagnosis Screen. 

 

 

 

Data Recording 

Move to Data Recording Screen. 

 

Summary of Contents for K-SCAN

Page 1: ...BAR 8 SPECIFICATION FUNCTION 9 TITLE VIEW 9 DATA VIEW LARGE 10 Select Data Items 11 DATA VIEW 12 GRAPH VIEW 13 Graph Setting 15 ACTIVE TEST 16 DIAGNOSIS 18 DATA RECORDING 20 Select Data Items 22 Data...

Page 2: ...onment Item Condition Remarks OS Microsoft Windows XP Resolution SVGA 800 x 600 Table 1 Software Requirements System Overview Figure 1 shows the system composition The K Scan gives instructions of Act...

Page 3: ...ing File GraphSetting txt Graph Setting File MakerCodeSetting txt Maker Code Setting File ActiveTestSetting txt Active Test Setting File PCodeSetting csv PCode Setting File K Scan pdf User Manual this...

Page 4: ...view window Available Screen Data View Large Data View Graph View Diagnosis Log File View Print Setting Show common dialog to set printer configuration Exit Exit the application View Title View Move t...

Page 5: ...bar Following table shows the toolbar composition And some buttons that are only available in particular screens Group Icon Name Overview File Open Log File Show common dialog to load a log file Avail...

Page 6: ...ting Show VIN Setting Dialog Data Recording Setting Show Data Recording Setting Dialog Available Screen Data Recording Operation Unit Switch Switch unit mode SI Deg C kPa USA Deg F inHg History Clear...

Page 7: ...K Scan PC User Manual SFT 20070171 Page 9 of 35 Specification Function Title View This is the start screen of the application Figure 2 Title View Screen 1 Image Display a logo image...

Page 8: ...by meters and values You can select 8 Data Items using Select Data Items Dialog that is shown by clicking View Setting menu or toolbar button If a selected Data Item does exist on ECU No Item will be...

Page 9: ...tems See Select Data Items 6 Toolbar Print button Print a screen image 7 Toolbar Unit Switch button Switch unit mode 8 When this screen is displayed When the ECU is not connected the ECU connection wi...

Page 10: ...esponds Index Data Item name of each Data Item Value sensor values of each Data Item Unit units of each Data Item 2 Toolbar Save button Save a screen data as csv format file 3 Toolbar Print button Pri...

Page 11: ...ds You can select 8 Data Items using Graph Setting Dialog that is shown by clicking View Setting menu or toolbar button You can also select a type of graph parallel and overlay using Graph Setting Dia...

Page 12: ...he left after 10 seconds These graphs will be cleared when you move to other screens 2 Selected Data Item Display a current value of Data Item 3 Toolbar Print Print a screen image 4 Toolbar View Setti...

Page 13: ...be displayed on the graph 2 Data Items Combo box Select Data Item of the channel 3 Data Items button Select plot color of the channel 4 View Mode Select a view mode Parallel Each channel will be displ...

Page 14: ...of 35 Active Test This function is to execute Active Test items There are 8 Data Items in one page and you can scroll page by clicking and buttons You cannot click any button during Active Test excep...

Page 15: ...een done Running or XXX Sec Active Test is running now 4 When Active Test Error is occurred If failed to connect to the ECU while running Active Test the message 7 will be shown See Message List and A...

Page 16: ...70171 Page 18 of 35 Diagnosis This function is to display DTC Data Trouble Code of the ECU This screen displays DTC errors by 2 list boxes to show two types of DTC error current error and historic err...

Page 17: ...en data as csv format file 4 Toolbar Print button Print a screen data 5 Toolbar History Clear Clear historic DTC errors When you clicked the button the Message 14 will be shown See the Message List If...

Page 18: ...can also give the file name recording time and trigger setting using Data Recording Setting Dialog that is shown by clicking Data Recording Setting menu or toolbar button If there is no trigger the re...

Page 19: ...t value the recording will be started 6 High Display the limit value of high level trigger When sensor value of the Data Item becomes more equal than the limit value the recording will be started 7 Ti...

Page 20: ...select 8 Data Items Figure 12 Select Data Items Dialog 1 CH0 CH7 combo box Select a Data Item from a list The list is created when this dialog is created 2 OK button Save selection of Data Items and c...

Page 21: ...own 4 button Show a dialog to set the file name 5 Trigger check box Set the trigger mode enable or not 6 Channel Set a channel to a trigger It is possible to select CH0 CH7 7 Selected Item Display the...

Page 22: ...application or K Scan PDA application You can open a log file using common dialog that is shown by clicking View Setting menu or toolbar button You can also select a type of graph parallel or overlay...

Page 23: ...g a cursor to display the sensor values at the cursor position A passed time at the cursor position will be displayed in the text box Pan You can scroll graphs by dragging a plot area Zoom You can dra...

Page 24: ...raph 2 Data Items Combo box Select Data Item of a channel 3 Data Items button Select a plot color of a channel 4 View Mode Select a view mode Parallel Each channel is displayed in a separate graph Ove...

Page 25: ...this version 2 RS232C Port Number combo box Set the COM port It is possible to select COM port from COM1 COM10 and Auto If Auto is selected COM port is searched from COM1 to COM10 when the Back butto...

Page 26: ...national Flag Show the message12 See the Message List 3 French national Flag Show the message12 See the Message List 4 German national Flag Show the message12 See the Message List 5 Spanish national...

Page 27: ...f the voltage is not within a normal range it will be displayed in red 2 Range of permission High Display upper bound voltage within the normal range 3 Range of permission Low Display lower bound volt...

Page 28: ...VIN Vehicle Identification Number code of the ECU 3 Software Type Display a software type of the ECU 4 Software Version Display a hardware version of the ECU 5 Hardware Type Display a hardware type of...

Page 29: ...Write Code text box Input a VIN code to be set to the ECU 3 Set to ECU button Set inputted VIN code to the ECU When you clicked the button the Message 29 will be shown See the Message List If you sel...

Page 30: ...K Scan PC User Manual SFT 20070171 Page 32 of 35 About K Scan This dialog is used to display version information Figure 22 About K Scan Dialog 1 OK button Close this dialog...

Page 31: ...t exist 6 Cannot load the language DLL OK Title The DLL file of selected language does not exist 7 Cannot connect to the ECU OK Transfer Data View Data View Large Graph View Diagnosis Active Test Data...

Page 32: ...lick the back button 14 Would you like to clear all historic errors YESNODiagnosis When you click the History Clear button 15 Cannot clear historic errors OK Diagnosis The application failed to clear...

Page 33: ...ng When the ECU returned this error code 28 This function is not supported by the ECU OK Throttle Setting When the ECU returned this error code 29 Would you like to write VIN code YESNOVIN Setting Whe...