ME 3000SP
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 29 -
Fig 6-1.Screen of ME 3000SP
If you didn
’
t change the work mode of ME 3000SP,which means ME 3000SP is
working in
“
Auto Mode
”
:
While
“
PV Production
”
>
“
Home Consumption
”
(fig 6-1)
If the battery is not full.ME 3000SP will charge the battery.
While
“
PV Production
”
<
“
Home Consumption
”
(fig 6-1)
If the battery is not flat.ME 3000SP will discharge the battery.
Every time you change the CT connection,you need to restart ME 3000SP.Please
follow the following procedure:
1.
Turn OFF PV inverter.Turn ON some home appliances.
2.
Turn OFF AC circuit breaker(grid)/DC isolator(battery).Wait 5 minutes.
3.
Turn ON DC isolator(battery),then turn ON AC circuit breaker(grid).Wait 1
minute.
4.
Turn ON PV inverter.
6.4. Menu
In the main interface,press
“
back
”
button to enter main menu.The main menu has the
following five options:
Main Interface
Press“Back”
“Up”↑
“Down”↓
1.Enter Setting
2.Event List
3.System Information
4.Software Update
5.Energy Statistic