SOFAR 25~50KTLX-G3
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 25 -
SOFAR 36KTLX-G3
60.6A
SOFAR40KTLX-G3
4*50A
66.7A
SOFAR 45KTLX-G3
75.8A
SOFAR 50KTLX-G3
83.3A
SOFAR40KTLX-G3-HV
3*50A
53A
SOFAR 50KTLX-G3-HV
4*50A
66.2A
4.1. Electrical Connection
Figure 4-1flowchart for connecting cables to the inverter
4.2. Grounding Connection (PE)
Connect the inverter to the grounding electrode usingground cable
SOFAR 25~50KTLX-G3 is a transformerless inverter which requires the
positive pole and negative pole of the PV array are NOT grounded.
Otherwise, it will cause inverter failure. In the PV system, all
non-current-carrying metal parts (such as mounting frame, combiner box
enclosure, etc.) should be connected to earthed.
Note
Preparation: prepare the grounding cable (recommend greater than
16mm
²
yellow-green outdoor cable, refer to section 4.3)
Procedure:
Step 1
: Remove the insulation layer with an appropriate length using a wire
stripper shown as figure 4-2
)