Problems and solutions
Problem
Cause
Solution
(possible in the working site)
Frequency loss with heavy
and violent blows.
Very high back pressure on
the exhaust line.
Check if the exhaust line hose is
partially occluded, if the filters are
partially or totally blocked or if the
taps are partially or totally closed.
Remove the obstacle.
Even though the hammer
is lifted up, the tool does
not slide downward.
Insufficient greasing or dirt
entered between the bushings
guide and the tool.
In this case, take down the tool,
check the bush and eliminate the
seizing marks eventually present.
Then clean, grease and install the
tool again.
The hammer suddenly
stops after four or five
blows, just after touching
the ground surface.
The piston is at the bottom of
the automatic brake, andthe
tool is completely out.
In this case the material is usually
soft. The tool sticks out, but it does
not go in again. It is necessary to
load the hammer correctly and to try
and keep a constant load.
It is possible to improve the
operation by keeping the hammer as
much vertical as possible, while
working.
Oil leaking from the hose
connection block.
The O-Ring is damaged.
Take down the block and change the
seals.
Oil leaking from the hoses.
The rubber hose is damaged.
The rubber hose is screwed
badly.
Change the flexible hose.
Screw the hose joints better.
Contact Socomec technical assistance for any problem that you cannot solve by
just reading the following instructions.
CLEANING, MAINTENANCE AND CHECKS
21
Page
of 48
5
Nederland B.V.
Summary of Contents for MDO 1600 TS
Page 34: ...44 39 41 43 45 36 35 38 40 42 46 37 STROKE CHANGER 34 Page of 48 10 Nederland B V ...
Page 40: ...101 96 98 100 99 97 DISTRIBUTOR GROUP 40 Page of 48 13 Nederland B V ...
Page 42: ...107 104 106 101 105 109 108 103 102 ACCUMULATOR GROUP 42 Page of 48 14 Nederland B V ...
Page 46: ...129 132 125 134 127 128 126 133 130 133 131 GREASING SYSTEM 46 Page of 48 16 Nederland B V ...