              Fig.1                                                                            Fig.2

 

7.3 Install the meter onto the DIN Rail, then push the DIN Rail Clip of the meter to fix the meter   

See details in below Fig. 3 and Fig.4

 

     

 

                          Fig.3                                                                  Fig.4 

7.4 Do the connection according to the wiring diagram.

 

 

7.5 After connection, seal the terminal covers by the seal wires. 

Summary of Contents for COUNTIS E13X

Page 1: ...distribution system for household and commercial 2 Features and Technical Parameters 2 1 Features It can read grid parameters analyze the energy quality and load condition in the certain time period D...

Page 2: ...ding Singapore 408723 http www socomec com 1 2 Modes for data display a Auto scrolling mode the time interval is 5s b Button mode by external button for data checking The material of the meter case AB...

Page 3: ...EC62053 21 Rated Voltage 230V Rated Current 5 100 A Impulse Constant 1000imp kWh Frequency 50 60Hz Accuracy Class 1 0 LCD Display LCD 5 1 99999 9kW Working Temperature 20 65 Power Consumption 8VA 0 4W...

Page 4: ...Ubi Road 1 02 01 Meiban Industrial Building Singapore 408723 http www socomec com 3 A Impulse indicator B Button for data checking C RS485 Port D L Out E L In F Neutral wire G LCD screen 4 LCD Display...

Page 5: ...omec Innovative Power Solutions 11 Ubi Road 1 02 01 Meiban Industrial Building Singapore 408723 http www socomec com 4 4 2 LCD Parameters Parameters Switch 5 Wiring Connection Note 23 24 25 is for A G...

Page 6: ...485 communication converter doesn t have G port no need to connect For Neutral wire you can connect one N port and connect both 6 Dimensions Height 95 3 mm Width 18 2 mm Depth 72 mm Weight 0 1 kg N W...

Page 7: ...http www socomec com 6 Fig 1 Fig 2 7 3 Install the meter onto the DIN Rail then push the DIN Rail Clip of the meter to fix the meter See details in below Fig 3 and Fig 4 Fig 3 Fig 4 7 4 Do the connect...

Page 8: ...Building Singapore 408723 http www socomec com 7 8 Communication 8 1 This meter supports RS485 Protocol is Modbus RTU mode The default parameters meter ID 1 baudrate 9600bps data bit 8 Parity Even Sto...