14. GLOSSARY OF ABBREVIATIONS

FrEL 

Metrological firmware version

CS 

Checksum of metrological firmware

t.1 

Tariff 1

t.2 

Tariff 2

tot 

Total menu

SEtuP? 

Setup menu

Prl Primary M-BUS address
SEC. 

Secondary M-BUS address

bAu 

Communication speed in bauds (bits per second)

rES ALL 

Reset partial energy

SAVE? 

Confirm selection

Save and exit

Exit without saving

Continue without saving

Summary of Contents for COUNTIS E05

Page 1: ...COUNTIS E05 COUNTIS E06 MID www socomec com en countis e0x Single phase energy meter Direct 40 A M BUS COUNTIS E05 E06 INSTRUCTION MANUAL EN...

Page 2: ...o the electrical network and to the loads 10 7 MID COMPLIANCE 11 8 COMMUNICATION 12 8 1 General information 12 8 2 Recommendations 12 8 3 Communication structure 12 8 4 Communication tables 12 9 CONFI...

Page 3: ...3 EN COUNTIS E05 E06 545867A SOCOMEC 1 DOCUMENTATION All documentation on the COUNTIS E05 E06 is available online at www socomec com en countis e0x...

Page 4: ...igned to be repaired by the user For any questions related to the disposal of the device please contact SOCOMEC Failure to comply with the instructions of the device and this safety information can ca...

Page 5: ...of these instructions thoroughly before commissioning Check the following points as soon as you receive the package containing the unit The packaging is in good condition The unit has not been damaged...

Page 6: ...M BUS communication Bus 4 2 Functions Measures and displays total and partial energy Dual tariff management T1 T2 Electrical parameter measurements I U V f Power power factor M Bus communication MID v...

Page 7: ...ain zone In the case of a Code XX corrupt metrological settings return to Manufacturer 5 Value of the partial meter Flashing meter stopped 6 Active communication 7 Inductive value 8 Imported or export...

Page 8: ...A Power factor PF Apparent power S kVA Active power P kW Reactive power Q kvar Frequency f Hz Direction of current Logged data Total active reactive energy Ea Er kWh kvarh Total active and reactive e...

Page 9: ...o the safety instructions section 2 Hazards and warnings page 4 Keep away from electromagnetic interference generator systems Avoid vibrations with accelerations greater than 1 g for frequencies lower...

Page 10: ...PZ2 10 62 lb in 1 2 Nm max 6 2 Connection to the electrical network and to the loads The COUNTIS E05 E06 are intended for single phase networks with neutral M Bus 2 3 M Bus connection Pulse output 4 5...

Page 11: ...6 2 Connection to the electrical network and to the loads page 10 Fitting terminal covers After connecting the device ensure that the terminal covers are fitted properly and secured by the plastic se...

Page 12: ...ded JYSTY Nx2x0 8 mm twisted pair 0 5 mm If the distance of 1000 m is exceeded and or the number of devices is greater than 250 add a repeater to allow additional devices to be connected If there are...

Page 13: ...nge your communication settings How to browse through the programming mode is described in the following stages Function Where Buttons Press Switch pages within a menu Every page within a menu Realtim...

Page 14: ...UP menu press for 3 seconds to put the device into programming mode Press to go to the different screens 3s Primary M BUS address Secondary M BUS address Communication speed Reset partial energy to ze...

Page 15: ...f menu SETUP 3s Primary M BUS address 000 001 249 250 Secondary M BUS address 0 1 99999998 99999999 the address is specific to each device Baudrate 300 2400 9600 Reset energy Ea partial Ea partial Er...

Page 16: ...ple setting the communication address In SETUP mode see page 15 go to the Primary M BUS address screen Example changing the communication address to 243 3 3 x2 3 x4 3 x3 3 x1 Secondary M BUS address C...

Page 17: ...mported reactive energy ______________ Tariff 2 Imported active energy ______________ Tariff 2 Imported reactive energy ______________ Total imported active energy ______________ Total exported active...

Page 18: ...ve energy Tariff 2 Imported reactive energy Total imported active energy description in chapter 10 1 1 Total exported active energy description in chapter 10 1 1 Total imported reactive energy descrip...

Page 19: ...EC 10 1 1 Detailed view of the partial energy meter Total imported active energy Total imported reactive energy 10 1 2 Starting up the partial energy meter 3 sec 3 sec 3 sec 10 1 3 Stopping the partia...

Page 20: ...20 EN COUNTIS E05 E06 545867A SOCOMEC 10 1 4 Resetting the partial energy meter to zero 3 sec x1 3 sec...

Page 21: ...ars if there are connection or malfunction errors 11 1 Malfunction If you see this message Code xx the meter has malfunctioned and must be replaced 12 ASSISTANCE Causes Solutions Device not working Ch...

Page 22: ...ut consumption 0 5VA max per phase Startup current Ist 20mA Minimum current Imin 0 25A Transition current Itr 0 5A Reference current Iref 5A Permanent overload lmax 40A Intermittent overload 30 Imax f...

Page 23: ...arh Realtime active power 1 display 4 digit 00 00 99 99 kW Realtime reactive power 1 display 4 digit 00 00 99 99 kvar Realtime voltage 1 display 4 digit 000 0 999 9 V Realtime current 1 display 4 digi...

Page 24: ...W x H x D mm Modular width of 2 modules DIN 43880 18 x 90 x 70 Installation On DIN rail EN 60715 Connection capacity tightening torque See chapter 6 Connection page 10 Protection index Front IP51 casi...

Page 25: ...cksum of metrological firmware t 1 Tariff 1 t 2 Tariff 2 tot Total menu SEtuP Setup menu Prl Primary M BUS address SEC Secondary M BUS address bAu Communication speed in bauds bits per second rES ALL...

Page 26: ...Non contractual document 2016 Socomec SAS All rights reserved 545867A CORPORATE HQ CONTACT SOCOMEC SAS 1 4 RUE DE WESTHOUSE 67235 BENFELD FRANCE www socomec com...

Reviews: