background image

RS232 <=> RTC<=> RS485

Modem

4

SOCOMEC - Réf. : 874 669 A GB

INTRODUCTION

The modem RS232 <=> RTC <=> RS485 is designed to
satisfy industry’s demands on reliability and functiona-
lity in environments with high levels of interference. It has
an RS232 interface and works as a calling / answering
modem on 2-wire Leased Lines. The product can use
4-wire Leased Lines. It can handle rates up to
115.2 kbit/s on the terminal side and up to 33.6 kbit/s on
the line side.

Specific parameters can also be set in hardware using
DIP-switches.

The modem is equipped with transient protection on the
line side and a “watchdog” that monitors and automa-
tically resets the modem in the event of a fault. These
functions together with the possibility for remote confi-
guration makes the modem perfect for installation at
unmanned sites and prevents the need of costly service
trips.

The modem also has password protection and dial-back
security to ensure that only authorised users can commu-
nicate with the modem.

The modem is intended for mounting on a 35 mm DIN-
rail, where the modem is attached and locked in a single
action.

In the product there is also an RS485 interface allowing
multidrop connections to many types of industrial
equipment.

It also has a single digital input and output. The input
can be used to trigger a number of different user defined
events. The output is a relay that can also be triggered by
a number of different user defined events. Both the digi-
tal input and output are galvanically isolated from the
rest of the modem.

Description

• Extended temperature range -25 °C to +70 °C

• Data rate up to 33.6 kbit / s with Fast Connect

• Terminal rate up to 115.2 kbit / s

• 2-wire Leased Line (also 4-wire Leased Line)

• V.23 HDX with multidrop

• DTR and incoming data dialling

• DIP-switch configuration

• Watchdog

• Secure call back and access

• Industrial environment transient protection on all

interfaces

• Up to 11 data bits

• Tri-Galvanic isolation (interface / line / supply)

• Caller ID presentation and answering

• Remote configuration

• RS485 interface

• Digital I / O

• Dial backup for PSTN and Leased Line

Characteristics

Summary of Contents for 4899 0200

Page 1: ...MODEM RS232 RTC RS485 Operating instructions GB SOCOMEC GROUP SWITCHING PROTECTION UPS MAKE YOUR BUSINESS SAFE...

Page 2: ...ions ____________7 Interface specifications ___________________________9 INSTALLATION __________________________________14 Connections___________________________________14 LED indicators _____________...

Page 3: ...not open connected unit Hazardous voltage may occur within this unit when connected to power supply or TNV circuits CARE RECOMMENDATIONS Follow the care recommendations below to maintain full operati...

Page 4: ...d users can commu nicate with the modem The modem is intended for mounting on a 35 mm DIN rail where the modem is attached and locked in a single action In the product there is also an RS485 interface...

Page 5: ...These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Page 6: ...RS232 RTC RS485 Modem 6 SOCOMEC R f 874 669 A GB APPROVALS AND CONFORMITY Declaration of conformity INTER 068 A GB...

Page 7: ...80 AM 1 kHz 0 15 80 MHz Power frequency magnetic field EN 61000 4 8 Enclosure 100 A m 50 Hz 16 7 Hz 0 Hz Pulse magnetic field EN 61000 4 9 Enclosure 300 A m 6 4 16 s pulse Voltage dips and interruptio...

Page 8: ...relative humidity non condensing Altitude Operating 2000 m 70 kPa Reliability prediction MTBF MIL HDBK 217F Operating Service life Operating 10 years Vibration IEC 60068 2 6 Operating 7 5 mm 5 8 Hz 2...

Page 9: ...ection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required 1 External supply current capability for proper startup POWER LV Rated voltage 12 to 48 VDC 12 to 27 V...

Page 10: ...50 Hz 1 min Connection RJ 11C and Detachable screw terminal Connector size Detachable screw terminal 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required LEASED LINE LL Electrical specification 2 or 4 w...

Page 11: ...ine 2 kVrms 50 Hz 1 min I O 1 5 kVrms 50 Hz 1 min Galvanic connection to RS232 Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required 1 Miscellaneous Do...

Page 12: ...terminal DCE Connector size Detachable screw terminal 0 2 2 5 mm2 AWG 24 12 Shielded cable Not required 1 Miscellaneous Do not connect RS232 and RS485 simultaneously 1 Railway installation close to th...

Page 13: ...sure should be connected to the earthing system of an installation and may be directly connected to the protective earth GENERIC I O INTERFACE RELAY OUTPUT Electrical specification One change over con...

Page 14: ...1 Direction relative to this unit 1 2 3 4 5 6 7 8 9 RS485 Position Direction 1 Description Product marking No 3 In Out T A A Tranmit Receive T RS485 2 wire No 4 In Out T A A Tranmit Receive T RS485 2...

Page 15: ...set to always ON DTR OFF DTR signal is inactive Data carrier detect ON DTR signal is active REL OFF Reliable mode is OFF direct or normal mode Reliable mode ON Reliable mode is ON FLASH Reliable mode...

Page 16: ...aud ON 1 2 3 4 5 6 7 8 19 2 bit s ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 38 4 bit s ON 1 2 3 4 5 6 7 8 2400 bit s ON 1 2 3 4 5 6 7 8 57 6 bit s ON 1 2 3 4 5 6 7 8 4800 bit s ON 1 2 3 4 5 6 7...

Page 17: ...ON 1 2 3 4 5 6 7 8 RS485 enable RS232 disable RS485 ON 1 2 3 4 5 6 7 8 RS485 2 wire Leased Line 2 4 wire selection ON 1 2 3 4 5 6 7 8 Leased Line 2 wire ON 1 2 3 4 5 6 7 8 Leased Line 4 wire Selectio...

Page 18: ...Line termination ON 1 2 3 4 5 6 7 8 Use stored value for AT Kn ON 1 2 3 4 5 6 7 8 RTS CTS flow control enable AT K3 Flow control DTE interface ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8...

Page 19: ...2 3 4 5 6 7 8 V 34 33600 ON 1 2 3 4 5 6 7 8 Automatic line speed DIP switch settings S4 DIP SWITCH Selection of line speed and modulation ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8 Auto...

Page 20: ...A20 DIRIS A40 COUNTIS Ci Max 0 3 metre T T T T A T T B 2 wire termination Termination recommendations The RS485 line must be terminated In the modem the termination is combined with fail safe functio...

Reviews: