19
SOCOMEC - Réf. : 874 669 A GB
Modem RS232 <=> RTC <=> RS485
INSTALLATION
ON
1 2 3 4 5 6 7 8
Use saved parameters defined by AT+MS.
ON
1 2 3 4 5 6 7 8
V.21 300.
ON
1 2 3 4 5 6 7 8
V.23 1 200 hdx.
ON
1 2 3 4 5 6 7 8
V.22 1 200.
ON
1 2 3 4 5 6 7 8
V.22bis 2 400.
ON
1 2 3 4 5 6 7 8
V.32bis 4 800.
ON
1 2 3 4 5 6 7 8
V.32bis 7 200.
ON
1 2 3 4 5 6 7 8
V.32bis 9 600.
ON
1 2 3 4 5 6 7 8
V.32bis 12 000.
ON
1 2 3 4 5 6 7 8
V.32bis 14 400.
ON
1 2 3 4 5 6 7 8
V.34 19 200.
ON
1 2 3 4 5 6 7 8
V.34 24 000.
ON
1 2 3 4 5 6 7 8
V.34 28 800.
ON
1 2 3 4 5 6 7 8
V.34 33 600.
ON
1 2 3 4 5 6 7 8
Automatic line speed.
DIP-switch settings
S4 DIP-SWITCH
>
Selection of line speed and modulation
ON
1 2 3 4 5 6 7 8
Use stored values.
ON
1 2 3 4 5 6 7 8
Auto retrain disabled AT %E0.
>
Auto retrain control
ON
1 2 3 4 5 6 7 8
Use stored values.
ON
1 2 3 4 5 6 7 8
Data compression AT %C0 disabled.
>
Data compression control
ON
1 2 3 4 5 6 7 8
Use stored values.
ON
1 2 3 4 5 6 7 8
DCD and DSR always on, DTR ignored. AT & C0 &
D0 & S0
>
DCD, DTR and DSR control
ON
1 2 3 4 5 6 7 8
Use stored values.
ON
1 2 3 4 5 6 7 8
Restore factory default setting
(1)
>
Set modem to factory default
(1) Don’t leave S4: 1 in ON position if not intending to restore factory setting at every power on.