©2009 NETCONS, s.r.o.
Page 10 of 27
If a power failure occurs during
TURNON=123
/
TURNOFF=123
commands,
time of power failure is not included in the countdown, so e.g. you need to run
an appliance for a hour issuing
TURNON=60
command, but AC power is lost
after 30minutes and restored back say after 2hours, appliance will be running
for half an hour after power is restored back.
3.2
Managing by phone call
The Main switched output of IQSD-GSM can be also controlled by dialing the
number of its SIM card. Call is for most commands rejected by IQSD-GSM so its
use is free of charge, with exception for listening sounds using embedded
Microphone.
Behavior of IQSD-GSM to incoming calls must be configured in advance using
RING command per following table.
SMS Command
Description
SMS Response
Type
RING=NOACTION
No action is performed, call is
rejected
RING=NOACTION – OK
Cfg
RING=RESTART
Change (negate) status of Main
switched output for time
preconfigured by command
RESTARTTIME, call is rejected.
RING=RESTART – OK
Cfg
RING=SWITCH
Change (negate) status of Main
switched output, call is rejected.
RING=SWITCH – OK
Cfg
RING=MIC
Monitoring of sound in surrounding
environment via integrated
microphone for one minute, call is
answered.
RING=MIC – OK
Cfg
RING?
Get current configuration of RING
action, active setting is in ()
parentheses.
RING=(NOACTION),RESET
, SWITCH, MIC
Cfg
3.3
Timing setup
Following table summarizes settings of time interval of
RESTART
command and
ringing period used by
RINGON
command and by alerts by dialing a number
under an alarm condition.
SMS Command
Description
SMS Response
Type
RESTARTTIME=XX Configures time of RESTART
command. Range is 1 to 180
seconds.
RESTARTTIME=XX – OK
Cfg
RESTARTTIME?
Get current configuration of
RESTARTTIME parameter.
RESTARTTIME
=10 seconds
Cfg
RINGONTIME=XX
Configures how long will IQSD-GSM
keep ringing during a call, initiated by
RINGON command or sending alarm
alert. Range is 20 to 60 seconds.
RINGONTIME=XX – OK
Cfg