Features 

Appliance control over SMS, by call or manually 
Remote restart of appliances 
Temperature monitoring 
Digital sensors monitoring 
Analogue sensor monitoring 
Programmable event-driven controller 
Alarm detection 
Monitoring of sound using integrated microphone

 

Dimensions 

90x53x58mm 

Weight 

0.1kg netto 

Operating temperature 

0 to +50 ˚C 

Humidity 

Max. 80%, non-condensing 

Operating temperature 

0 to +50 ˚C 

Mounting 

DIN rail (35mm, EN50022), 3 modules wide 

Compliance 

CE 

 

6.1

 

Operation, maintenance and safety recommendations 

 

 

Do not modify product in any way and do not operate product modified 

any way. Warranty is void when product was disassembled or modified 
in any way. 

 

Product is not fused; ensure it is installed in fused electric installation 
only. 

 

Product is not intended as security device, alarm functions are just 
auxiliary. 

 

Product can be operated only indoor office/house environment. Do not 

expose it to humid, wet nor chemically aggressive environment. 

 

Product is not designed for industrial operation with aggressive 
environment. 

 

Before use, please check, if mobile phones can be used in the area. In 

not, please don‟t put product into operation, it can have negative 
influence to other electronic systems. 

 

Don‟t expose product to vibrations, shaking or fall downs to avoid 
product damage. 

 

When use sound monitoring for taping purposes, ensure you have prior 
permission to do it from affected people. 

 

Load current 10A/0.1A is valid for resistive load. If you need to switch 
an non-resistive or higher current load, use an external contactor rated 

for target load among the product. Switching a non-resistive load or 
higher than nominal rating currents can cause permanent damage of 
switching elements, which is not covered by warranty.  

Summary of Contents for IQsocket DIN/IQSD-GSM

Page 1: ...User guide www IQsocket eu Intelligent power sockets IQsockettm DIN IQSD GSM makes your life more comfortable User Guide IQSD GSM documentation v1 1 1 R5...

Page 2: ...7 Response messages settings 13 3 8 Scheduler feature 14 3 9 Counters 15 3 10 Alarms 15 3 10 1 Defining phone numbers for SMS and ringing up alerts 16 3 10 2 Battery charge alarm 16 3 10 3 AC mains p...

Page 3: ...or medical applications Product must be mounted on DIN rail 35mm EN50022 inside a suitable enclosure providing environmental protection The product contains no serviceable parts or internal adjustment...

Page 4: ...DIN rail mounting IQsocket IQSD GSM helps to control any electric appliance remotely over GSM network IQSD GSM is managed by SMS messages or phone call It can work also as a programmable regulator wit...

Page 5: ...ter not included in product package o External detector of opened door window shake detector not included in product package o Any other external detector with contact output can be connected Alarm de...

Page 6: ...of 27 2 Installation Before starting installation please read this manual and take into account Important information section at beginning of this manual 2 1 Wiring the IQSD GSM Wire connections per f...

Page 7: ...g SIM PIN usage using appropriate command usually located in Settings phone menu Now you can remove the SIM card from phone and insert it into your IQSD GSM Insert SIM card with inactive PIN code auth...

Page 8: ...AND e g 3366STATUS o With pre configured security password by command SMSPIN 3366 COMMAND e g STATUS o with un configured security password SMSPIN There are two kinds of commands Control commands labe...

Page 9: ...STARTTIME Restarted Ctrl STATUS Get status of IQSD GSM Outputs Temperature digital and voltage inputs AC mains Backup Battery charge time and GSM signal Output OFF OFF Temperature 22 5 C NA Input OFF...

Page 10: ...ESTART Change negate status of Main switched output for time preconfigured by command RESTARTTIME call is rejected RING RESTART OK Cfg RING SWITCH Change negate status of Main switched output call is...

Page 11: ...t current settings of Date time DATE yy mm dd hh mm ss zz OK Cfg 3 5 Manual Control IQSD GSM can be controlled manually using push button located in the bottom left corner of front panel see drawing i...

Page 12: ...inserted SIM card IQSD GSM allows to define up to 20 permitted phone numbers each containing up to 15 numerals In case of using SMSPIN right before each SMS command is placed PIN code without any spac...

Page 13: ...od and executed successfully For this purpose we implemented response messages confirming each command or informing you when an error is detected In case of SMS commands you will be notified by back S...

Page 14: ...ION at time hh mm every day of week DOW SCHEDULER hh mm DOW ACTION OK Ctrl SCHEDULER hh mm Remove scheduler record for particular time hh mm SCHEDULER hh mm OK Ctrl SCHEDULER Get list of all scheduler...

Page 15: ...crements on change of Digital Input2 COUNTER2 0 Ctrl COUNTER3 Get status of Counter3 increments on change of Main switched output COUNTER3 0 Ctrl COUNTER4 Get status of Counter4 increments on change o...

Page 16: ...NUMBER ALL OK Cfg ALARMNUMBER LIST Get list of phone numbers for alarm alerts using SMS message and call back LIST 421265440655 Cfg When generating alerts numbers in list are processed per their order...

Page 17: ...in parentheses POWERFAULT NO INFO Cfg When AC mains fails for time longer than 10 seconds device will send following SMS alert message to the numbers set by ALARM command Power failed In case power is...

Page 18: ...language user must know at least basic knowledge of algorithmization Program is defined in form of row there can be up to 6 such rows A program row can be inserted using ID command and removed using...

Page 19: ...nored like if it is always true E_VoltageIn means evaluation condition for VoltagIn input having syntax beginning with condition symbol or followed by the value in Volts itself Some examples 5 conditi...

Page 20: ...l program rows ID0 OK Ctrl Once program rows were entered into IQSD GSM use command PROGRAM to start its execution SMS Command Description SMS Response Type PROGRAM START Start execution of the progra...

Page 21: ...nding following SMS command ALARM 421903123456 Then enter following two program rows ID1 0 1 S 1 Closed ID2 1 0 S 0 Open And then let s start the program issuing SMS command PROGRAM START When needed...

Page 22: ...en there is Log 0 level at both inputs turn off the Main switched output Enter following two program rows ID1 0 1 1 TURNON ID2 0 1 1 TURNON ID3 1 0 0 0 TURNOFF And then let s start the program issuing...

Page 23: ...n case of permitted phone numbers list is active but used number is not included in it Timeout 10 minutes interval since power on or since last configuration command has timed out In order to continue...

Page 24: ...e per second indicates SIM card with active PIN authorization It is necessary to disable the PIN authorization using a GSM phone RELAY yellow blinking fast indicated a HW failure 5 Factory default set...

Page 25: ...isolated max 30V input detection threshold 1V 1x Analog voltage sensing 0 30VDC 0 24VAC Resolution 1V 2x Temperature sensor inputs 1 Wire for Dallas DS18B20 sensor Voltage outputs 5VDC 100mA protected...

Page 26: ...roduct is not intended as security device alarm functions are just auxiliary Product can be operated only indoor office house environment Do not expose it to humid wet nor chemically aggressive enviro...

Page 27: ...ct family uses following ordering code system IQSx y z Example IQSD GSM Product family W WALL R RACK D DIN Product model GSM IP RS232 HDO IPGSM Output Socket type F Schuko E French Optional accessorie...

Reviews: