2.3 Indication

REL/

 

Adjust reading to zero   

 

 

 

 

 

Capacitor

 

Alternating Current (AC) 

 

 

nF / µF

   

Nanofarad / Microfarad

 

Direct Current (DC) 

 

 

 

mF 

 

 

Millifarad

mV

   

Millivolt    

 

 

 

 

 

Hz/kHz/MHz

  Hertz / Kilohertz / Megahertz

V

 

 

Volt   

 

 

 

 

 

 

 

 

Duty cycle

mA

   

Milliampere   

 

 

 

 

AUTO 

 

Auto range / Measurement

µA

   

Microampere  

 

 

 

 

CAT IV

 

 

Overvoltage category 4

A

 

 

Ampere   

 

 

 

 

 

CAT III

 

 

Overvoltage category 3

  

Negative  

 

 

 

 

 

 

 

 

Ground Potential

 

 

Signal strength of NCV

 

 

Over range

H

Freeze / Hold reading

 

 

Non Contact Voltage

Ohm  

 

 

 

 

 

 

 

 

 

NCV function display active

K

Kilohms   

 

 

 

 

 

 

 

 

Celsius /  Fahrenheit

M

Ω 

Megaohms

 

 

Low battery display

Diode test 

 

 

 

 

 

 

 

 

Reading Recorded

       Continuity 

 

 

 

 

 

 

 

 

Non-contact frequency

NCV

NCV

NCF

°C/F°

MAX/MIN
MAX-MIN

Summary of Contents for ENGINEER DMM

Page 1: ...Instruction Manual Specification SAS095v1 ENGINEER DMM 6000 count true RMS digital multimeter...

Page 2: ...test probes behind the finger guards Caution refer to the instruction manual Danger of electric shock Construction is double insulated Product should be recycled as electronic waste Conforms to EU st...

Page 3: ...Digital Multimeter Test Leads 9v DF22 6LR61 1604 battery fitted K type temperature Ni Cr and Ni Si sensor temperature range measurable 40 C to 250 C Operating Manual 2 2 Features True RMS 6000 Count...

Page 4: ...liampere AUTO Auto range Measurement A Microampere CAT IV Overvoltage category 4 A Ampere CAT III Overvoltage category 3 Negative Ground Potential Signal strength of NCV Over range H Freeze Hold readi...

Page 5: ...f NCV Temp 6 MAX MIN MAX MIN button press once For recorded voltage current resistance and temp reading 7 REL relative reading button press once Adjust reading to zero except NCV range 8 Hold button...

Page 6: ...mponent to be measured is safely isolated from any voltage source Turn the rotary switch to the resistance setting Ensure that the test leads are connected to the correct meter terminals Check the tes...

Page 7: ...ent range required Ensure the test leads are connected to the correct meter terminals for the range selected Press the select button to choose AC or DC as required Connect the test probes in series wi...

Page 8: ...ier and secure with the screws Fit rubber over mould 4 2 Trouble Shooting If required clean with a damp cloth and mild detergent Do not use abrasives or solvents With the exception of the batteries an...

Page 9: ...0 15 5 digits DC Current A manual range Range Resolution Accuracy 600 0 A 000 1 A 0 12 3 digits 6000 A 1 A 0 12 3 digits AC Current mA manual range Range Resolution Accuracy 60 00mA 00 01mA 0 15 5 di...

Page 10: ...cy does not include clamp meter error Resistance manual range Range Resolution Accuracy 600 0 000 1 0 7 5 digits 6 000K 0 001K 0 6 2 digits 60 00K 00 01K 0 6 2 digits 600 0K 000 1K 0 7 2 digits 6 000M...

Page 11: ...de Type K thermocouple error General Specification Power Supply 1 x 9V 6F22 6LR61 1604 battery Low battery Indication 2 6 V appox Overvoltage category CAT III 1000V CAT IV 600V Operating Temperature 0...

Page 12: ...CCHECK Calibration Checkbox SOC CB400 Non Trip Installation Testing Calibration Checkbox SOC VIP150 Craftsman Voltage Tester SOC SP400 Proving Unit SOC VVDPRO Vibrating Non Contact AC Voltage Detector...

Reviews: