Frequency for Electrical (Auto range)

sensitivity 1.0V rms

Range

Resolution

Accuracy

9.999Hz -
55.00KHz

0.001Hz -
0.01KHz

+0.15% +3

digits

Diode

Range

Resolution

Accuracy

3.000V

0.001V

+10% +5

digits

Non-Contact AC Voltage detect

LC Displays EF
and NCV

When >100 VAC LED blinks
faster and buzzer sounds

AC / DC external clamp adaptor input

Range

Resolution

Accuracy

600A @ 1mV / 1A

0.1A

+0.8% +5 digits

Note: Accuracy does not include clamp meter error.

Resistance manual range

Range

Resolution Accuracy

600.0

000.1

+0.7% +5

digits

6.000K

0.001K

+0.6% + 2

digits

60.00K

00.01K

+0.6% +2

digits

600.0K

000.1K

+0.7% +2

digits

6.000M

0.001M

+1.5% +5

digits

60.00M

00.01M

+2.5% +6

digits

Capacitance Auto range

Range

Resolution

Accuracy

9.999nF

0.001nF

+5% +7 digits

9.999µF

0.001µF

+5% +5 digits

99.99µF

0.01µF

+10% +10 digits

9.999mF

0.001mF

+10% +10 digits

99.99mF

0.01mF

+10% +10 digits

Duty Cycle

Range

Resolution

Accuracy

0.1 - 99.9%

0.1%

+1.2% +2 digits

Non-contact Frequency (NCF) detection

Range

Resolution

Accuracy

45Hz - 70Hz  (50 -
500 VAC)

0.01Hz

+2Hz

Summary of Contents for ENGINEER DMM

Page 1: ...Instruction Manual Specification SAS095v1 ENGINEER DMM 6000 count true RMS digital multimeter...

Page 2: ...test probes behind the finger guards Caution refer to the instruction manual Danger of electric shock Construction is double insulated Product should be recycled as electronic waste Conforms to EU st...

Page 3: ...Digital Multimeter Test Leads 9v DF22 6LR61 1604 battery fitted K type temperature Ni Cr and Ni Si sensor temperature range measurable 40 C to 250 C Operating Manual 2 2 Features True RMS 6000 Count...

Page 4: ...liampere AUTO Auto range Measurement A Microampere CAT IV Overvoltage category 4 A Ampere CAT III Overvoltage category 3 Negative Ground Potential Signal strength of NCV Over range H Freeze Hold readi...

Page 5: ...f NCV Temp 6 MAX MIN MAX MIN button press once For recorded voltage current resistance and temp reading 7 REL relative reading button press once Adjust reading to zero except NCV range 8 Hold button...

Page 6: ...mponent to be measured is safely isolated from any voltage source Turn the rotary switch to the resistance setting Ensure that the test leads are connected to the correct meter terminals Check the tes...

Page 7: ...ent range required Ensure the test leads are connected to the correct meter terminals for the range selected Press the select button to choose AC or DC as required Connect the test probes in series wi...

Page 8: ...ier and secure with the screws Fit rubber over mould 4 2 Trouble Shooting If required clean with a damp cloth and mild detergent Do not use abrasives or solvents With the exception of the batteries an...

Page 9: ...0 15 5 digits DC Current A manual range Range Resolution Accuracy 600 0 A 000 1 A 0 12 3 digits 6000 A 1 A 0 12 3 digits AC Current mA manual range Range Resolution Accuracy 60 00mA 00 01mA 0 15 5 di...

Page 10: ...cy does not include clamp meter error Resistance manual range Range Resolution Accuracy 600 0 000 1 0 7 5 digits 6 000K 0 001K 0 6 2 digits 60 00K 00 01K 0 6 2 digits 600 0K 000 1K 0 7 2 digits 6 000M...

Page 11: ...de Type K thermocouple error General Specification Power Supply 1 x 9V 6F22 6LR61 1604 battery Low battery Indication 2 6 V appox Overvoltage category CAT III 1000V CAT IV 600V Operating Temperature 0...

Page 12: ...CCHECK Calibration Checkbox SOC CB400 Non Trip Installation Testing Calibration Checkbox SOC VIP150 Craftsman Voltage Tester SOC SP400 Proving Unit SOC VVDPRO Vibrating Non Contact AC Voltage Detector...