Frequency for Electrical (Auto range)
sensitivity 1.0V rms
Range
Resolution
Accuracy
9.999Hz -
55.00KHz
0.001Hz -
0.01KHz
+0.15% +3
digits
Diode
Range
Resolution
Accuracy
3.000V
0.001V
+10% +5
digits
Non-Contact AC Voltage detect
LC Displays EF
and NCV
When >100 VAC LED blinks
faster and buzzer sounds
AC / DC external clamp adaptor input
Range
Resolution
Accuracy
600A @ 1mV / 1A
0.1A
+0.8% +5 digits
Note: Accuracy does not include clamp meter error.
Resistance manual range
Range
Resolution Accuracy
600.0
Ω
000.1
Ω
+0.7% +5
digits
6.000K
Ω
0.001K
Ω
+0.6% + 2
digits
60.00K
Ω
00.01K
Ω
+0.6% +2
digits
600.0K
Ω
000.1K
Ω
+0.7% +2
digits
6.000M
Ω
0.001M
Ω
+1.5% +5
digits
60.00M
Ω
00.01M
Ω
+2.5% +6
digits
Capacitance Auto range
Range
Resolution
Accuracy
9.999nF
0.001nF
+5% +7 digits
9.999µF
0.001µF
+5% +5 digits
99.99µF
0.01µF
+10% +10 digits
9.999mF
0.001mF
+10% +10 digits
99.99mF
0.01mF
+10% +10 digits
Duty Cycle
Range
Resolution
Accuracy
0.1 - 99.9%
0.1%
+1.2% +2 digits
Non-contact Frequency (NCF) detection
Range
Resolution
Accuracy
45Hz - 70Hz (50 -
500 VAC)
0.01Hz
+2Hz