Calibration Procedure (CAL 3)
Please remove the JP3 jumper before you start the calibration process.
to toggle among the menu options. And press
to confirm.
In Calibration menu, press
1. SEL maximum capacity
Display
Descriptions
LoAd
Set maximum capacity as 6 kg.
06d
LoAd
Set maximum capacity as 15 kg.
15d
LoAd
Set maximum capacity as 30 kg.
30d
2. A0
Display
Descriptions
A0 0(off)
Zero tracking function is disabled.
A0 1(on)
Zero tracking function is activated.
3. Zero Point Calibration
Display
Descriptions
The right window shows AD Value of Zero weight. Wait until
the AD value becomes stable, press
Pnt. 0 XXXXXX
to confirm.
4. Setup calibration weight
Display
Descriptions
Put 1/3 or 2/3 or 3/3 of full load on the weighing pan. The
right window shows AD Value of the load. Wait until the AD
value becomes stable, press
Pnt. CAL XXXXXX
to confirm.
Display
Descriptions
The right window will cycle display the 1/3,2/3,3/3 of full
load. When the weight displayed equal to the load weight,
press
Pnt. CAL 1/2/30000
to confirm. The window will show “done”.
Remove the load from the weighing pan, and the scale will restart and the calibration is done.
11