Chapter 5. Gauges
■
Hourmeter
Figure 4.1 - Hourmeter
The hour me ter is ba si cally an elec tric clock. It ac -
cu
mu
lates time when the mas
ter key switch is
turned on. The hour me ter can not be re set. An EPV
qual i fied ser vice tech ni cian can use it to tell when it
is time for the pe ri odic main te nance listed in the
main te nance man ual.
■
Level Bubble
Figure 4.2 - Level Bubble
A level bub ble is mounted on the base. Watch the
bub ble while you set the sta bi lis ers. Lower the sta -
bi
lis
ers, front ones first, one (1) at a time just
enough to cen ter the bub ble in the cir cle on top of
the gauge. When the bub ble is cen tral the plat form
is level and the plat form can be safely raised.
■
Hydraulic Oil Level
Figure 4.3 - Hydraulic Oil Level
The hydraulic oil level gauge is on the side of the
hydraulic oil tank. It shows the actual level of oil
inside the tank. Read it only when the booms are
fully lowered and stabilisers are raised in the travel
position. The oil level should be or - 6mm
(¼”) of the line.
EPV16 – 13642-1
Rev A
page 5 - 1