There are two ways to get to the oil filter on a
Kubota engine.
1. One way is to rotate the turntable (4) about
30° clockwise with respect to the chassis (5)
then reach through the hole (6) in the bottom
of the turntable (4).
Use caution to avoid burns as the engine and
exhaust manifold might be hot.
2. The second way is to reach over the engine.
■
Circuit Breakers
With the exception of the GFCI outlet at the
platform, there are no circuit breakers on the ATB
42/50 that are accessible to an operator.
Circuit breakers on the ATB 42/50 automatically
reset themselves about one minute after tripping.
When a circuit breaker trips that will not reset, or
if it resets automatically but trips again,
immediately attempt to lower the platform to the
ground by using normal operating procedures.
If normal procedures do not work, use
EMERGENCY procedures (see “Emergency
Operation” chapter 9) to lower the platform.
If the cause of the problem is not immediately
obvious, refer the problem to a qualified
service technician.
If the 15 A circuit breaker on the side of the outlet
trips, disconnect whatever you plugged into the
outlet, wait one minute, then press the circuit
breaker button back in.
If the ground fault circuit breaker in the GFCI
outlet trips, disconnect whatever you plugged into
the outlet, wait one minute, then press the
RESET button back in.
If a circuit breaker trips two times in a row, refer
the problem to a qualified service technician.
page 5 - 2
ATB 42/50 – 0161987
5. Automatic Shut-Offs and Circuit Breakers
CAUTION
CAUTION