background image

7

ENGLISH

Important Information 

The M110 SC bundle contains one M110 SC base station with Ethernet cable and one M110 SC  handset, a rechargeable battery 
pack, and one handset charger with power adapter.

Setting up, configuring, and using base station and handset

For information on setting up, configuring, and using the base station and the handset, please refer to the user's manuals listed on 

the MSC-series product pages at www.snom.com.

Intended Use

The handset of the M110 SC is designed for professional use with the M110 SC base station.  The M110 SC base station is designed 

for professional use with the M110 SC handset.  Any other use is considered unintended use.  Any modification or reconstruction 

not described in the user manual is considered unintended use.

Safety precautions

  CAUTIONS:

Please read these precautions and the instructions on how to set up and use the phone thoroughly before using the phone.  Save 
this guide and do not give the phone to third parties without it.  
The nameplate is located at the bottom or rear of the product.

Charger, power supplies/adapters, rechargeable batteries

 Use only a power converter (AC/DC adapter) delivered with the device or Snom approved. Other power supplies may damage or 
even destroy it.
 Use only the rechargable batterie packs delivered with the device, model no. Ni-MHAAA550mAh 2.4V (NI-MHAAA550*2), 2.4 V, 550 
mAh, supplier Yiyang Corun Battery Co., Ltd.  Before use, please read the information on the safe and proper handling, use, disposal, 
and replacement of the batteries on page 9.

•  Power of M110 SC handset charger:  

 

 EU:  VTPL, model number VT05EEU06045, 100-240V, 50/60Hz, 150mA, 6V, 450mA

 

UK:  VTPL, model number VT05EUK06045, 100-240V, 50/60Hz, 150mA, 6V, 450mA

•  Power of M110 SC base station

:  

 

 Power over Ethernet (PoE):  IEEE 802.3af, Class 2.  

 

If PoE is not available, use the power adapter (not included in delivery, available separately):

 

- EU:  Ten Pao, model no.: S005BNV0500080, 100-240V, 50/60Hz, 150mA, 5V, 800mA

 

- UK:  Ten Pao, model no.: S005BNB0500080, 100-240V, 50/60Hz, 150mA, 5V, 800mA 

Placement of base, handset charger, cables, and cords

•   

 Warning:

  Power adaptors shall be installed near the equipment and shall be easily accessible.

•  Mount the device only at heights not exceeding 2 m.
•   Avoid placing the devices' cords where people may trip over them.  Avoid placing the cords where they may be exposed to 

mechanical pressure as this may damage it.  If the power supply cord or the plug is damaged, disconnect the device and contact 

qualified service personnel.

•   Charger, power adapter, and cord are for indoor installation only.  

Not for outdoor installation

!  

•   The operational temperature for base station and handset is between 0°C and + 40°C, humidity 95% non.-condensing.  The 

charging temperature for the handset is between 0°C and +40°C.  

•   Do not install product in rooms with high humidity (for example, in bathrooms, laundry rooms, damp basements). Do not 

immerse product  in water and do not spill or pour liquids of any kind onto or into any parts of it.

•   Do not install product in surroundings at risk for explosions and do not use the handset in such surroundings (paint shops, for 

example). 

Do not use the phone if you smell gas or other potentially explosive fumes!

•  Install the base at a minimum distance of 100 cm (39") to persons and animals.
• 

 Medical devices might be adversely affected.  Please consider the technical ramifications when installing the devices in a 
doctor‘s office, for example.

Summary of Contents for M110 SC Bundle

Page 1: ...M110 SC Bundle Quick Installation Guide SIP DECT 8 line base station and SIP DECT handset en de fr it es...

Page 2: ...Carga de batter a 11 hrs Delivery content Lieferumfang Contenu de la bo te Contenuto della confezione En la caja Quick Installation Guide Ba tte ry Pa ck BT 16 43 92 BT 26 43 92 2 4 V 55 0m Ah Ni MH...

Page 3: ...OUNT SLOT M110 SC Manufactured in China Snom Technology GmbH Wittestr 30 G 13509 Berlin Germany WALL MOUNT SLOT DC 5V 800mA Use only power supplies listed in the user manual Removing the wall bracket...

Page 4: ...les 2 tasti funzioni sensibili al contesto 2 teclas de funzi n depen diendo del contexto Loudspeaker Lautsprecher Haut parleur Altoparlante Altavoz End call cancel Au egen beenden Raccrocher annuler R...

Page 5: ...rcomunicador Volume Lautst rke Volumen External loudspeaker Externer Lautsprecher Haut parleur externe Altoparlante esterno Altavoz externo Battery compartment Akkufach Compartiment de la pile Alloggi...

Page 6: ...ombin Allum lorsqu au moins un compte SIP est enregistr teint lorsque aucun compte SIP n est enregistr Caratteristica della stazione base Tasto di localizzazione del telefono cordless Premere brevemen...

Page 7: ...06045 100 240V 50 60Hz 150mA 6V 450mA UK VTPL model number VT05EUK06045 100 240V 50 60Hz 150mA 6V 450mA Power of M110 SC base station Power over Ethernet PoE IEEE 802 3af Class 2 If PoE is not availab...

Page 8: ...l devices Consult a physician or the manufacturer of the medical device to determine if they are adequately shielded from external radio frequency RF energy or if you have any other questions concerni...

Page 9: ...of used batteries according to the instructions Charge the battery only inside the handset The full performance of a new battery is achieved only after two or three complete charge and discharge cycle...

Page 10: ...evant European directives This device complies with the Radio Equipment Regulations 2017 and the essential health safety and environmental requirements of all relevant UK legislation The declaration o...

Page 11: ...rmationen ber die sichere Verwendung und Entsorgung der Akkus auf Seite 13 Stromversorgung der Ladeschale des M110 SC Mobilteils VTPL Modellnummer VT05EEU06045 100 240V 50 60Hz 150mA 6V 450mA EU Strom...

Page 12: ...ion Bringen Sie keine Kreditkarten oder andere magnetische Datentr ger in die N he des Ger ts da auf diesen enthaltene Daten hierdurch gel scht werden k nnen Medizinische Ger te Der Betrieb von Funkge...

Page 13: ...war Verwenden Sie den Akku nicht bei extrem niedrigem Luftdruck in gro en H hen Lassen Sie den Akku in einer Umgebung mit extrem hohen Temperaturen und oder extrem niedrigem Luftdruck kann dies eine E...

Page 14: ...nformit t Dieses Ger t entspricht der Richtlinie 2014 53 EU und den grundlegenden Gesundheits Sicherheits und Umweltanforderungen aller relevanten europ ischen Richtlinien Die Konformit tserkl rung ka...

Page 15: ...ion VTPL mod le no VT05EEU06045 100 240V 50 60Hz 150mA 6V 450mA EU Alimentation en courant de la station de base Power over Ethernet PoE IEEE 802 3af Classe 2 S il n y a pas de PoE utilisez utilisez u...

Page 16: ...sultez un docteur ou le constructeur de l appareil m dical afin de d terminer s il est suffisamment blind contre des missions de fr quence radio externes ou si vous avez d autres questions ce sujet Et...

Page 17: ...tteries au feu ou dans un four chaud ni n crasez ou coupez m caniquement une batterie qui pourrait provoquer une explosion Chargement et d chargement stockage des batt ries ATTENTION Risque d explosio...

Page 18: ...Veuillez contacter les autorit s locales pour d avantage d informations Conformit aux Standards Cet appareil est marqu CE et conforme la Directive 2014 53 EU et aux standards de s curit de sant et env...

Page 19: ...aratamente non incluso Adaptatore Ten Pao modello S005BNV0500080 100 240V 50 60Hz 150mA 5V 800mA Collocazione del base del caricabatterie e gli dei cavi Avvertenza gli adattatori di alimentazione devo...

Page 20: ...sitivo all interno di strutture sanitarie in cui non ne ammesso l uso Ospedali e cliniche utilizzano spesso apparecchiature sensibili a energia esterna di in radiofrequenza Dispositivi medici impianta...

Page 21: ...atteria raggiunge la piena prestazione solo dopo che stata scaricata e ricaricata completamente per due o tre volte Le batterie possono essere ricaricata e scaricata centinaia di volte ma alla fine il...

Page 22: ...Direttiva 2014 53 EU e agli standard europei di salute sicurezza ed ambientali Scarica la dichiarazione di conformit all indirizzo www snom com conformity Eventuali modifiche cambiamenti e l apertura...

Page 23: ...V 450mA EU Alimentaci n del estaci n base Power over Ethernet PoE IEEE 802 3af Clase 2 Si PoE no est disponible use un fuente de alimentaci n no incluido en la caja disponible por separado Adaptador T...

Page 24: ...si tiene dudas respecto a este asunto Apague el dispositivo en instalaciones cl nicas cuando las se ales colgadas en estas reas se lo indiquen Los hospitales o instalaciones cl nicas pueden usar equip...

Page 25: ...provocar una explosi n Carga y descarga almacenaje PRECAUCI N Riesgo de explosi n si la bater a se reemplaza por un tipo incorrecto Cargue la bater a solo dentro del auricular El tel fono se alimenta...

Page 26: ...ales Contacte con su autoridad local para m s informaci n Cumplimiento con la normativa Este tel fono tiene el marcado CEC y cumple con la Directiva 2014 53 EU y los est ndares de salud seguridad y me...

Page 27: ...di conformit Snom Technology GmbH dichiara che M110 SC telefono cordless telefono cordless e M110 SC stazione base sono conformi alla direttiva sulla compatibilit elettromagnetica 2014 53 UE alla dire...

Page 28: ...Technologies Canada Ltd Suite 222 13888 Wireless Way Richmond B C V6V 0A3 Canada Phone support 339 227 6160 Snom Technology GmbH 130 avenue Joseph Kessel 78960 Voisins le Bretonneux France Tel 33 1 8...

Reviews: