Confidential BTP-R880NP Programming Manual
- 55 -
GS o n
[Function]
Set barcode parameter of QRCODE
[Format]
ASCII
GS
o
m
nA
nB
nC
Hex
1D
6F
m
nA
nB
nC
Decimal
29
111
m nA nB nC
[Range]
m = 0 ,1
≤
nA
≤
255 ,0
≤
nB
≤
1,1
≤
nC
≤
2
[Description]
The meaning of parameter n is shown as below:
Parameter
Meaning
m m=0(Fixed)
nA Basic
element
width
nB
Language mode
0:Chinese 1:Japanese
nC
Symbol type
1:Original type 2:Enhanced type(Recommended)
[Notes]
When the value of the parameters is beyond the range, the command is not valid.
GS p n
[Function]
Set barcode parameter of barcode PDF417
[Format]
ASCII
GS
p
nA nB nC nD nE nF
Hex
1D
70
nA nB nC nD nE nF
Decimal
29
112
nA nB nC nD nE nF
[Range]
1
≤
nA
≤
10, 1
≤
nB
≤
100, 3
≤
nC
≤
90, 1
≤
nD
≤
30, 1
≤
nE
≤
7, 2
≤
nF
≤
25
[Description]
The meaning of parameter n is shown as below:
Parameter
Meaning
nA
Appearance to height
nB
Appearance to width
nC
Lines limit
nD
Columns limit
nE
Basic element width
nF Basic
element
height
GS q n
[Function]
Set correction grade of barcode PDF417
[Format]
ASCII
GS
q
n
Hex
1D
71
n
Decimal
29
113
n
[Range]
0
≤
n
≤
8
[
Notes]
Set correction grade of PDF417 code, the higher the correction grade is the bigger the
capacity of the barcode is.
GS w n
[Function]
Set bar code width
[Format]
ASCII
GS
w
n