86
Chapter 8
Scope Multimeter
This Scope Multimeter module provides all the tools needed for performing electrical and
electronic circuit tests and for monitoring signals and circuit activity. The Scope Multimeter works
interactively with other modules. Selecting “View Meter” from a Guided Component Test or
Scanner Test starts the Scope Multimeter module.
:$51 ,1*
Risk of electrical shock.
• Read the Safety Information provided for important warnings on the use of this product
• This product is intended for Measurement Category I (for example, automotive 12V
systems), do not use this product for Measurement Categories II, III, and IV.
• Measurement Category I is for performing measurements on circuits not directly
connected to MAINS or MAINS circuits (an example of a MAINS circuit is 120V AC or
240V AC household or industrial electricity), do not connect this product to MAINS or
MAINS circuits.
Electrical shock can cause personal injury, equipment damage, or circuit damage.
IMPORTANT:
Maximum rated transient over voltage impulse is 500 volts, do not exceed the rated
transient over voltage.
8.1 Getting Started
The Scope and Multimeter module enables the following functions:
•
Lab Scope
•
Ignition Scope
•
Graphing Multimeter
•
Digital Multimeter
8.1.1 Capabilities
The following tables detail the software and hardware capabilities.
NOTE:
i
200V to 400V scales are not to be used to measure signals greater than 50VAC (rms) or 75VDC.
IMPORTANT:
Do not use the Low Amp Probe to measure current on conductors at a potential greater than
46VAC peak or 70VDC.
Summary of Contents for VERUS
Page 1: ...User Manual EAZ0061B58A Rev E ...
Page 4: ...iv ...