• 9 •
QUICKSETUP
The first time the machine is used, a quick startup guide appears:
the operator is guided through the steps described at the start of
the PRELIMINARY OPERATIONS section. From the SETUP MENU,
select QUICKSETUP, the following screen is displayed:
Press ENTER to proceed with QUICKSETUP, the user will be
guided throught the following steps:
Language selection
Measure units selection
License plate recording
Date and time selection
Setup header print
Vacuum settings
Leak check test
Tank filling
Follow the instructions displayed. At the end of the procedure,
press ENTER to print a summary report of the guided procedure.
Press ESC to exit.
NOTE:
If the guided procedure is not completed, it will be
displayed again the next time the machine is switched on.
NOTE:
To display the QUICKSETUP at any time, select from the
menu of the same name under SETUP.
SET DATE / TIME
The machine keeps date and time settings even if it is not used
for around one year. From the SETUP MENU, select SET DATE /
TIME:
Use keypad to change date and time. Press ENTER to confirm, or
press ESC to return to SETUP menu without saving the changes.
For example, to insert the date January 21
st
2015, select the
month then type “1” using the keypad, select the day then type
“21” using the keypad, select the year then type “2015” using the
keypad; press ENTER to confirm and exit.
SETUP HEADER PRINT
The printout can be personalized by entering 4 lines containing
the workshop’s details (e.g. name, address, telephone number
and e-mail).
From the SETUP, select SETUP HEADER PRINT:
Use the keypad to modify the 4 lines, then press ENTER to return
to SETUP menu.
NOTE:
the numerical keys include an alphabet that is used
similar to text messaging; for example: press “2” once to display
“2”, twice to display “A”, three times for “B”, four times for “C”, five
times for “a”, six times for “b”, seven times for “c”, eight times for
“2” again.
VACUUM SETTINGS
Allows to modify the default vacuum time and the default time
of check.
From the SETUP, select VACUUM SETTINGS, default setting is
displayed:
Each value can be modified, within the values shown in
parentheses.
NOTE:
Press DEFAULT to restore default values:
Vacuum time
25 min
Time of check
2 min
Vacuum rising
1 psi
R134a
SETUP
SETUP HEADER PRINT
Welcome to POLARTEK Quick Setup
Press ENTER to proceed
Press ESC to exit.
R134a
SETUP
QUICKSETUP
R134a
SETUP
SET DATE / TIME
Date
Time
xx
xx
xx
xx
xx xxxx
PM
Hours Minutes Seconds
Month Day Year
Vacuum rising
Time of check
Vacuum Time
VACUUM SETTINGS
Pressing INFO set default values
R134a
SETUP
VACUUM SETTINGS
xx
xx
xx
psi
9 psi
Summary of Contents for POLARTEK HYBRID EEAC332
Page 2: ... 2 ...
Page 4: ... 4 WARRANTY 40 NOTES 41 ...
Page 41: ... 41 NOTES ...
Page 42: ... 42 ...
Page 43: ... 43 ...