9
EEWB333B
2.1 ELECTRIC INSTALLATION
ANY ELECTRICAL WIRING MUST BE PER-
FORMED BY LICENSED PERSONNEL.
ALL SERVICE MUST BE PERFORMED BY AN
AUTHORIZED SERVICE TECHNICIAN.
Check on the plate of the machine that the electrical
specifi ca tions of the power source are the same as
the machine. The machine uses 115VAC, 60Hz, 1Ph,
4.0 Ampere.
NOTE:
Any electrical outlet installation must be
verifi ed
by a licensed electrician before connecting the
balancer.
NOTE:
This machine performs a self-test routine on start-
up. There will be a delay of several seconds before
the display is activated.
• Plug the power output plug (1,Figure 8a) of the adapter
into the power socket of the balancer (2).
• Plug the adapter into the mains power outlet.
Figure 6
B.
Mount the SAPE Arm extension (1,Figure 7) to
the SAPE disc (2,Figure 7).
Figure 7
C.
Install the accessory pins (Figure 8). Tighten fi rmly.
Figure 8
D.
Place cones and other accessories onto the acces-
sory pins.
Figure 8a
Rear side
A
B
C
2
1
2
1
Summary of Contents for EEWB333B