15
5.
Open the by-pass valve, and power up until oil is seen flowing out of the bleeder hose.
(No Air Bubbles). Bleed at least 1 gal. of hydraulic fluid through the system.
6.
Remove the bleeding hose and reinstall the bleeder cap. Replace breather/filler cap.
7.
Power up until slave side carriage reaches the carriage stops.
8.
Close the by-pass valve and lower lift (both sides) until both carriages are fully
collapsed. Power up and lower (14”) lift a few times. When lift is fully down, open
the by-pass valve and raise the slave side 2-3” higher than the power side. Close the
by-pass valve.
9.
Power up, and lower lift onto the first safety, on the power side. Open the by-pass
valve and lower slave side onto the same first safety. Close the by-pass valve. Lift is
now synchronized hydraulically.
10.
Both power and slave sides must be completely down.
11.
Check and add hydraulic fluid to power pack before cycling lift.
12.
Install safety covers, and safety release lever knob. Securely.
13.
After anchoring, set up a vehicle on the lift to make sure hydraulics are operating
properly.