TROUBLESHOOTING GUIDE
20
NOZZLE
The nozzles should be lubricated with non-water soluble grease or light oil regularly.
Clogging of the nozzles causes the pump pressure to build up too high and cleaning is
required.
1. Make sure Pressure Washer On/Off switch is
set to Off and spray gun trigger is locked.
2. Clear blockage in nozzle by inserting the nozzle
cleaning needle (provided) through center hole.
3. After cleaning, remove the needle from nozzle
and store for future use.
LUBRICATION
This Pressure Washer does not require any maintenance on the pump or motor.
Both assemblies are pre-lubricated and sealed, requiring no additional lubrication.
A small amount of oil leakage is normal. If oil leakage
persists or became worse, contact our customer service department.
WATER INLET SCREEN (FILTER)
The Pressure Washer is equipped with a water inlet
screen to protect the pump from foreign debris.
CAREFULLY
remove debris from the screen using a
nonabrasive and dull object (finger or Q-Tip). Make sure
screen is not torn or broken.
Do not operate Pressure Washer without screen filter in
place. Impurities entering pressure pump can cause internal damage.
COOLING SYSTEM
The air louvers, located in and around the Pressure Washer housing must be kept
clean and free of any obstructions to ensure proper air cooling of the motor and
pump during operation.
19
SCREEN
Problem
Probable Cause
Solution
Unit will not start (when
trigger is depressed)
1. Unit is not turned on.
2. Loose or disconnected
plug.
3. GFCI has tripped.
4. Thermal Switch has
tripped.
5. No AC power at the
outlet.
6. Main voltage supply is
too low.
7. Extension cord is too
long or wire size too
small.
8. Defective ON/OFF
Switch.
9. Defective GFCI Plug.
10. Defective Gun.
1. Press ON/OFF Switch
into ON position.
2. Reconnect Plug.
3. Push reset button on
plug.
4. Allow to cool and
restart unit.
5. Main circuit breaker is
tripped or outlet is faulty.
6. Make sure main supply
voltage is adequate
(See specifications).
7. Remove extension cord
or use proper extension
cord (See instructions).
8. Call Customer Service:
1-888-278-8092.
9. Call Customer Service:
1-888-278-8092.
10. Turn off the unit.
Remove the Gun from
the high pressure hose.
Redirect the outlet to a
safe direction and
switch ON the unit. If
the unit starts and
water comes out of the
front, the Gun may
need to be replaced.
Call Customer Service:
1-888-278-8092.