ARCNET 5 Port HUB Controller
Datasheet
SMSC TMC2005-JT
Page 27
Revision 1.1 (07-24-07)
DATASHEET
OPERATIONAL DESCRIPTION
MAXIMUM GUARANTEED RATINGS*
Stresses above those listed may cause permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other condition above those indicated in the operational sections of this
specification is not implied.
(Note) When powering this device from laboratory or system power supplies, it is important that the Absolute
Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit voltage spikes or
“glitches” on their output when the AC power is switch on or off. In addition, voltage transients on the AC power line
may appear on the DC output. If this possibility exists it is suggested that a clamp circuit be used.
Vss = 0V
ITEM SYMBOL
RATING
UNIT
POWER SUPPLY VOLTAGE
VDD
-0.3 +7.0
V
INPUT VOLTAGE
VIN
-0.3 VDD +0.3
V
OUTPUT VOLTAGE
VOUT
-0.3 VDD +0.3
V
AMBIENT TEMPERATURE
Tstg
-40 +125
°C
STANDARD OPERATING CONDITION
Vss = 0V
ITEM SYMBOL
RATING
UNIT
POWER SUPPLY VOLTAGE
VDD
4.5 – 5.5
V
AMBIENT TEMPERATURE
Ta
0 - +85
°C
DC CHARACTERISTIC - INPUT PIN
SYMBOL ITEM
CONDITION
MIN
MAX
UNIT
XTLI, nPLLTST
3.5
V
V
IH
High Level Input Voltage
Others
2.2
V
V
IL
Low Level Input Voltage
0.8
V
I
IH
High Level Input Current VIN=VDD -10
10 uA
I
IL
Low Level Input Current VIN=VSS -10
10 uA
I
IL
With pull-up
Vin=VSS
-200
-10
uA
I
OZ
Output Leak Current
VOUT=VDD or VSS
-10
10
uA
I
DD
Dissipation Current
Operating
100
mA