Issue 002 - October 2018 | SmithsEP.co.uk | 5
Application
Kiosk, Trafalgar and Tube are primarily
intended for installation at floor level against
a wall or window.
Tube may be installed in any orientation on the
floor or against the wall. Natural convectors can
help reduce condensation on floor to ceiling glass
when position in front of them, providing a
consistent blanket of warm exiting air from
the emitter.
These products are designed for use on standard
two-pipe pumped central heating systems.
Pipe connections are 15mm and may be
used as either flow or return. TRV should be at
Flow end. This product is not suitable for
one-pipe systems.
The heater must be installed In line with best
plumbing practices and with reference to industry
standards, such as the CIBSE Domestic Heating
Design Guide. Isolating valves (as supplied) must
be fitted to system flow and return connections.
Failure to fit isolating valves may mean that the
product is not serviceable in the event of failure.
Wall mounted - horizontal
Except Tube
Floor mounted
Inverted mounted
Wall mounted - vertical
Tube can be installed in the
vertical plane, but the TRV
should be at low level.
Î
Î
Î
P
Product mounting options
Product performance
Heat output
150
200
Model A
Tube .5m
500
Tube 1m
1000
Tube 1.5m
1500
Tube 2m
2000
A
Product
length
∆T °C
20 ∆T
30 ∆T
40 ∆T
50 ∆T
60 ∆T
70 ∆T
Kiosk
0.5m
22
39
60
83
109
136
1.0m
73
133
202
281
367
459
1.5m
125
226
345
479
626
783
2.0m
176
320
487
677
884
1106
Trafalgar
0.5m
39
72
110
154
201
253
1.0m
133
243
373
519
681
856
1.5m
226
414
635
885
1160
1459
2.0m
320
585
898
1250
1640
2062
Tube
0.5m
36
64
96
132
170
212
1.0m
88
157
237
325
421
524
1.5m
141
251
378
519
671
836
2.0m
193
344
519
712
922
1148
Entering ambient air temperature of 20°C
Outputs in Watts. In accordance with EN442 - BSRIA verified
210
A
92
Model A
Kiosk .5m
500
Kiosk 1m
1000
Kiosk 1.5m
1500
Kiosk 2m
2000
206
A
180
Model A
Trafalgar .5m
500
Trafalgar 1m
1000
Trafalgar 1.5m
1500
Trafalgar 2m
2000