6. On the back side of the electrical panel there will be a stain relief cable clamp,
Unscrew and fasten onto the exiting harness to the electrical panel (See Fig 5).
(Actual electrical panel may vary)
7. Refit the electrical panel. Ensure wiring is clear from fan mouths using provided cable
ties if necessary.
8. Attach the controller previously removed from machine to the wall plate supplied
ensure that when the knob is turned fully anti clockwise it aligns with the low mark on
the plate. (Fig 4)
9. Route the 10mm cable (harness) that has been attached to the heater to the pre fitted
pattress box and connect the wires as shown in fig 3.
10. Attach the controller and wall plate to the patress box and secure with the screws
provided.
11. Refit front panel to machine.
12. Turn on electrical supply and any other external controls (room stat / timer etc.) and
check that the machine is working correctly by adjusting speed controller.
__________________NOTES__________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
__________________________________________
4
Linking multiple units together
UVC 90/120
Fan
Fan
M
F
M
F
F M
Fan
Fan
M
F
M
F
F
F
M
F
Speed Controller
12 m
Le ad
12 m
Le ad
12 m
Le ad
Male
Connector
Female
Connector
Fan
Fan
M
F
M
F
F M
UVC 90/120
UVC 90/120
(Diagram showing three Caspian UVC units being linked with three separate External Control Harnesses (Shown in different colours))
5
Fig 4
TO FAN
CABLE EXIT
FIX CABLE CLAMP TO
HOLES ON THE BACK OF
THE BRACKET
Fig 5