Correct installation

Incorrect installation

Caution

The mounting accessories provided can only be used for solid walls as shown in the drawing above. 
Improper installation may cause the water heater to dislodge. 

If the walls do not meet the minimum 
standards for bearing the water heater load, 
increase the mounting reinforcement 
accordingly. 

Ensure the power cord is installed above the 
inlet and outlet. Installation below this point 
may cause water to flow down the cord to the 
power source, leading to accidents. 

Plumbing connection

Do not alter the installation position or block the relief valve. Connect the safety valve provided with this 
unit to the inlet of the water heater (inlet pipe has a blue cap). The arrow points to the direction of 
water flow (to the heater). The safety valve must be connected to the discharge pipe, mounted 
downwards to a floor drain in a frostless environment. As water may drip from the discharge pipe 
during operation of the heater, a floor drain should be provided nearby. The pipes should not be 
blocked.

11

Fig. 3

Fig. 4

Fig. 5

Summary of Contents for HPW-60A

Page 1: ...Heat Pump HPW 60A HPW 80A User Guide...

Page 2: ...world Water heaters are one of the highest energy consumers in a household Using green technologies you can save up to 80 of energy At AOS Bath we believe in empowering home owners with knowledge so y...

Page 3: ...out High efficiency insulation Pressure relief valve safety valve Anode protection Installation 9 Mounting Mounting procedures and precautions Mounting guidelines Plumbing connection Water inlet and...

Page 4: ...er and replace the anode rod by contacting the local authorized dealer In this way the service life of the heat pump system will be extended effectively Prior to any maintenance or repair of the heat...

Page 5: ...owledge They should be given supervision or instructions concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the...

Page 6: ...cy V Hz 230 50 230 50 Temperature range C 35 75 5 35 75 5 Max min ambent temperature C 18 38 5 18 38 5 Noise level dB 40 40 Rated water pressure MPa 0 8 0 8 Inlet outlet connection inches Waterproof g...

Page 7: ...o save 40 of energy or 200 year Touch screen control panel Instead of waiting 20 minutes for hot water as with conventional heaters get hot water in 2 minutes at the touch of a button Instant heating...

Page 8: ...the tank inlet The valve will relieve pressure in the tank when it exceeds 0 8MPa in the form of intermittent water droplets The discharge port of the relief valve and the condensation pipe should be...

Page 9: ...of the system A floor drain must be provided near the heater Vertical installation of the water heater is strictly prohibited Mounting procedures and precautions The installing surface must be capabl...

Page 10: ...ow Model L mm HPW 60A 260 HPW 80A 380 A nylon expansion tube must pass through the hole of the mounting bracket first and then inserted into the drilled holes It is necessary to use a special inner he...

Page 11: ...point may cause water to flow down the cord to the power source leading to accidents Plumbing connection Do not alter the installation position or block the relief valve Connect the safety valve provi...

Page 12: ...e insulation of the fixed wiring must be protected by an insulating sleeving with a temperature rating of at least 80 C Ensure the water heater is reliably grounded The earth wire must be longer than...

Page 13: ...of water Installing the remote control For convenience of operation the control holder may be installed on a wall near the water heater The remote controller must be installed at a dry area Drill two...

Page 14: ...s revert to factory settings Programmed settings will only be retained if heater remains switched on for over 4 hours The system can keep clock settings for 72 hours without power Heating indicator Ho...

Page 15: ...eset temperature can be set between 35 C to 75 C 3 Setting the clock Ensure the indicator lights for Timer 1 and Timer 2 are off Hold down the Program button for 3 seconds till the time on the screen...

Page 16: ...s or decrements Press the Program button again to finalize the start time and to start setting the end time The end time is set in the same manner as the start time While setting this timing the indic...

Page 17: ...d turbo mode heat pump and speed element heating 7 MAX and AES Toggle the AES button to activate either the MAX mode AES mode or both AES mode will not run simultaneously with timers and will take pre...

Page 18: ...nst excessive pressure build up The valve relieves pressure when it exceeds 0 8MPa in the form of intermittent water droplets Users should check the valve regularly by lifting the handle on the valve...

Page 19: ...charge pipe It is recommended that the tank be flushed to remove sediments which may have built up during operation Specific operating procedures are as follows 1 Disconnect the power 2 Screw off the...

Page 20: ...flushed to remove sediments which may have built up during operation Specific operating procedures are as follows 1 On the right side of the system remove the filter by pulling the edge of the filter...

Page 21: ...r heater and be sure to use sealant Display E1 Black wire of two core terminal open circuit or short circuit Contact local authorized dealer Display E2 White wire of two core terminal open circuit or...

Page 22: ...erence 2 Compressor not installed horizontally Contact local authorized dealer Reset prompt Fault in grounding system Contact local authorized dealer Normal sounds of water heater in heat pump efficie...

Page 23: ...ion or tamper with the relief valve Hot water over 50 C will scald Always test the water temperature by mixing it with cold water before coming into contact with it This appliance is not intended for...

Reviews: