USER MAINTENANCE

A. General Housekeeping (Continuous).

1.

Keep boiler area clear and free of combustible
materials and obstructions to the free flow of
combustion and ventilation air to the boiler.

2.

Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of the boiler or any
other appliance.

3.

Do not store or use sources of hydrocarbons 
in the vicinity of the boiler. Sources of hydro-
carbons include bleaches, cleaners, chemicals,
sprays, paint removers, fabric softeners and
refrigerants.

4.

Check Safety Relief Valve for water leakage. 
If leakage exists, contact a qualified service
agency.

B. Inspect Vent System (Monthly): 

Vent pipe must

be sealed with no separations, obstructions, or
sags.

WARNING

Product Safety Information

Refractory Ceramic Fiber Product

This appliance contains materials made from
refractory ceramic fibers (RCF). Airborne RCF,
when inhaled, have been classified by the
International Agency for Research on Cancer
(IARC), as a possible carcinogen to humans.
After the RCF materials have been exposed to
temperatures above 1800°F (980

°

C

)

, they can

change into crystalline silica, which has been
classified by the IARC as carcinogenic to
humans. If particles become airborne during
service or repair, inhalation of these particles
may be hazardous to your health.

Avoid Breathing Fiber Particulates and Dust

Suppliers of RCF recommend the following
precautions be taken when handling these
materials:

Precautionary Measures:
Provide adequate ventilation.

Wear a NIOSH/MSHA approved respirator.

Wear long sleeved, loose fitting clothing and
gloves to prevent skin contact.

Wear eye goggles.

Minimize airborne dust prior to handling and
removal by water misting the material and
avoiding unnecessary disturbance of materials. 

Wash work clothes separately from others.
Rinse washer thoroughly after use.

Discard RCF materials by sealing in an airtight
plastic bag.

First Aid Procedures:
Inhalation: If breathing difficulty or irritation
occurs, move to a location with fresh clean air.
Seek immediate medical attention if symptoms
persist.

Skin Contact: Wash affected area gently with a
mild soap and warm water. Seek immediate
medical attention if irritation persists.

Eye Contact: Flush eyes with water for 15
minutes while holding eyelids apart. Do not rub
eyes. Seek immediate medical attention if
irritation persists.

Ingestion: Drink 1 to 2 glasses of water. Do not
induce vomiting. Seek immediate medical
attention.

USER’S INFORMATION MANUAL

PAGE 6

WARNING

Service on this boiler should be undertaken only
by trained and skilled personnel from a qualified
service agency. Inspections should be performed
at intervals specified in the Installation,
Operation and Maintenance Manual and this
User’s Information Manual. Maintain manuals in a
legible condition.

Keep boiler area clear and free of combustible
materials, gasoline and other flammable vapors
and liquids.

Do not place any obstructions in boiler room
that will hinder flow of combustion and
ventilation air.

CAUTION

Vent system operates under positive pressure
when venting horizontally or vertically with 3"
diameter AL294C vent. Leakage in vent system
will spill products of combustion into building.
Severe vent system leakage can cause carbon
monoxide poisoning.

Summary of Contents for GVX-Series

Page 1: ...erty damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to...

Page 2: ...he call for heat ends See Figure 5 5 Gas Valve The gas valve monitors pilot flame and regulates gas flow to the burners and pilot See Figure 1 6 Safety Relief Valve A device which protects the boiler...

Page 3: ...witches Pressure Switch continuing power through closed contacts BR 2 and flame roll out switch 6 Gas valve energizes a Ignitor on b Pilot gas on igniting pilot 7 Pilot flame detected a Ignitor off b...

Page 4: ...R S INFORMATION MANUAL PAGE 4 Figure 1 Control Locations Figure 2 Safety Relief Valve Hook Up Installation with Air Elimination in System Piping Figure 3 Safety Relief Valve Hook Up with Air Eliminati...

Page 5: ...trol knob counterclockwise to ON 9 Replace control access panel if applicable 10 Turn on all electrical power to the appliance 11 Set thermostat or operating control to desired setting 12 If the appli...

Page 6: ...Wear long sleeved loose fitting clothing and gloves to prevent skin contact Wear eye goggles Minimize airborne dust prior to handling and removal by water misting the material and avoiding unnecessar...

Page 7: ...e flame is yellow and lazy follow instructions TO TURN OFF GAS TO APPLIANCE see Figure 4 and contact qualified service agency 8 Adjust all thermostats to lowest setting to shut down boiler 9 Replace B...

Page 8: ...TEL 413 562 9631 FAX 413 562 3799...

Reviews: