![Smith-Root PES User Manual Download Page 9](http://html1.mh-extra.com/html/smith-root/pes/pes_user-manual_1305833009.webp)
USER’S GUIDE
7
2015
LOAD SETUP, SELECT, SAVE
SETUP
The LOAD SETUP button is used to review
the various electrical parameters defining
a dose. The PES
®
is pre-programmed with
10 stored, predefined doses (See PRE-
PROGRAMMED DOSES, SPECS.).
After pressing LOAD SETUP, the
and
buttons are used to scroll through
the predefined doses (defined by sets of
electrical parameters), and the SELECT
button is used to load the set of parameters
for use. These parameters can be modified
by the user and, if desired, these new
parameters can be stored for recall.
The dose to be delivered is programmed
by the user and is defined by PULSE TYPE,
TIME, VOLTS, FREQ, and DUTY CYCLE.
INTERACTING WITH THE
PES
®
Once the unit is turned on, a series of buttons and the centrally located
display on the front panel of the device are used to interact with the PES
®
and to program the electrical doses to be output.
OPERATIONS
Use the
and
buttons to review the
parameters and SELECT to load the
parameters into memory. Display messages
will prompt the user for the required input.
After all parameters have been reviewed,
press SAVE SETUP, use the
and
buttons to select the memory location
(page) where the newly defined dose will
be saved, press SELECT. Use the SAVE
SETUP button to save the settings. Up to
10 sets of parameters (doses) can be saved
into memory.
Note:
Because there is a potential
for interactions among the electrical
parameters defining a “dose”, a review of
ALL dose parameters is required when a
change is made to any of the parameters
defining a dose (PULSE TYPE, TIMER,
VOLTS, FREQ, DUTY CYCLE).