Commands
3
36
System Commands
Syntax
#sys –o set –p br –v <baud rate>
#sys –o get –p br
#sys –o get –p sn
#sys –o get –p ver –v <code>
#sys –o set –p lliop –s <prj sel> -f <prj filename>
#sys –o get –p lliop –s <prj sel>
Parameters
<baud rate>
9600
,
19200
,
38400
,
57600
,
115200
, or
230400
.
<code>
sys
or
driver
.
<prj sel>
Project number, as selected by the PRJ_SEL[5..0] lines
on the Low-Level Interface connector.
<prj filename>
Project file associated to
<the prj sel>
setting.
Description
Set or get instrument’s internal parameters.
Examples
Sets a new serial baud rate:
#sys -o set –p br –v 115200
>
Retrieves the instrument’s serial number:
#sys -o get -p sn
00100>
Associates the project
test.wnp
to the project number 1:
#sys –o set –p lliop –s 1 -f \projects\test.wnp
>