background image

4

Product Dimensions

30" (76.2 cm) Cooktop

Model SIMU530

A. 21

5

16

" (54.1 cm)

B. 30³⁄

4

" (78.2 cm)

C. 3¹⁄

8

" (8 cm)

36" (91.4 cm) Cooktop

Model SIMU536

A. 21

5

16

" (54.1 cm)

B. 36

5

16

" (92.0 cm)

C. 3¹⁄

8

" (8 cm)

Cabinet Dimensions

IMPORTANT:

 If installing a range hood or microwave hood 

combination above the range, follow the range hood or 

microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.

A. 29½" (75.0 cm) on 30" (76.2 cm) models
 33¹⁄

16

" (84.0 cm) on 36" (91.4 cm) models

B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
  and bottom of uncovered wood or metal cabinet (24" [61 cm]
  minimum clearance if bottom of wood or metal cabinet is covered
  by not less than ¹⁄

4

" [0.6 cm] flame retardant millboard covered with

  not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
  steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33.0 cm) recommended upper cabinet depth
E. 2" (5.1 cm)
F. 19

5

16

" (49.0 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
  within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of
 countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of
 cabinet
J. 29½" (75.0 cm) on 30" (76.2 cm) models
 33¹⁄

16

" (84.0 cm) on 36" (91.4 cm) models

K. 1" (2.5 cm) minimum distance to nearest left and right side
  combustible surface above cooktop
L. 1" (2.5 cm) minimum clearance between back wall and countertop
M. 

IMPORTANT: 

For proper ventilation, provide a vent of ³⁄

16

" (5 mm)

  under the countertop, in the front of the cabinet. The ventilation
  opening is to extend the full length of the cooktop cutout. See the
  following illustration.

NOTES: 

After you make the countertop cutout, some 

installations may require notching down the base cabinet side 

walls to clear the cooktop base. To avoid this modification, use a 

base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 5¹⁄

8

" (13 cm) depth clearance from the 

countertop to the top of the drawer (or other obstruction) in base 

cabinet is required.

C

A

B

C

A

B

D

A

E

I

J

K

G

H

L

C

F

B

M

M

³⁄₁₆

(5.0 mm)

Summary of Contents for W10818570A

Page 1: ...CURIT DE LA TABLE DE CUISSON 9 EXIGENCES D INSTALLATION 10 Outillage et pi ces 10 Exigences d emplacement 10 Sp cifications lectriques 12 INSTRUCTIONS D INSTALLATION 13 Pr paration de l emplacement 13...

Page 2: ...instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safe...

Page 3: ...projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate T...

Page 4: ...depth E 2 5 1 cm F 195 16 49 0 cm G 18 45 7 cm minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop H Junction box or outlet 12 30 5 cm minimum from botto...

Page 5: ...junction box and the cooktop so that the cooktop can be moved if servicing becomes necessary in the future Do not cut the conduit The length of conduit provided is for serviceability of the cooktop A...

Page 6: ...ooktop cutout 2 Position brackets in the center of the vertical centerline and align the upper edge of the brackets so that they are flush with the countertop 3 Attach the brackets in the cutout with...

Page 7: ...f it is present 3 Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector A UL listed or CSA approved conduit connector 4 Tighten sc...

Page 8: ...ire from cooktop D 3 wire cable from cooktop E Junction box F White wire from home power supply G UL listed wire connector H Black wires I UL listed or CSA approved conduit connector with wire bushing...

Page 9: ...07 15 Printed in Italy Imprim en Italie W10818570A SP PN W10825305 2015 All rights reserved Tous droits r serv s...