Installation
96
The nozzles not provided are available at Authorised Service Centres.
8 LPG G30/31
AUX
SR
R
DUAL int.
DUAL ext.
Rated heating capacity (kW)
1.0
1.8
3.0
0.9
4.0
Nozzle diameter (1/100 mm)
50
65
85
46
98
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced flow rate (W)
400
500
800
400
1600
Rated flow rate G30 (g/h)
73
131
218
65
291
Rated flow rate G31 (g/h)
71
129
214
64
286
9 LPG G30/31
AUX
SR
R
DUAL int.
DUAL ext.
Rated heating capacity (kW)
1.1
1.9
2.9
0.9
4.1
Nozzle diameter (1/100 mm)
50
65
81
46
94
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced flow rate (W)
450
550
800
450
1600
Rated flow rate G30 (g/h)
80
138
211
65
305
Rated flow rate G31 (g/h)
79
136
207
64
300
10 LPG G30/31
AUX
SR
R
DUAL int.
DUAL ext.
Rated heating capacity (kW)
1.0
1.8
2.9
1.0
4.0
Nozzle diameter (1/100 mm)
43
58
70
43
75
Pre-chamber (printed on nozzle)
(H2)
(M)
(Y)
(H2)
(S1)
Reduced flow rate (W)
400
500
850
400
1700
Rated flow rate G30 (g/h)
73
131
211
73
291
Rated flow rate G31 (g/h)
71
129
207
71
286
11 Town gas G110
AUX
SR
R
DUAL int.
DUAL ext.
Rated heating capacity (kW)
1.0
1.8
2.8
1.0
3.6
Nozzle diameter (1/100 mm)
145
185
260
140
320
Pre-chamber (printed on nozzle)
(/8)
(/2)
(/3)
(/8)
-
Reduced flow rate (W)
400
500
800
400
1400
12 Town gas G120
AUX
SR
R
DUAL int.
DUAL ext.
Rated heating capacity (kW)
1.0
1.8
2.8
1.1
3.7
Nozzle diameter (1/100 mm)
135
175
240
130
300
Pre-chamber (printed on nozzle)
(/8)
(/1)
(/3)
(/8)
-
Reduced flow rate (W)
400
500
800
400
1400