Instructions for the installer
41
7.5
Regulation of primary air
Referred to distance “
A
” in mm.
60 cm hobs with separable control panel.
Burner
G20
20 mbar
G30/G31
28/37 mbar
Auxiliary (1)
3.0
4.0
Semirapid r (2)
1.0
2.0
Semirapid l (3)
1.0
2.0
Rapid large (4)
1.0
3.5
Ultrarapid (5)
1.0
5.0
90 cm hobs with separable control panel.
Burner
G20
20 mbar
G30/G31
28/37 mbar
Auxiliary (1)
2.5
3.0
Semirapid (2)
1.0
2.0
Rapid (3)
1.5
1.5
Fish burner (4)
0.5
8.0
Ultrarapid (5)
1.5
3.0
60 cm hob with built-in control panel.
Burner
G20
20 mbar
G30/G31
28/37 mbar
Auxiliary (1)
3.0
4.0
Semirapid r (2)
1.0
2.0
Semirapid l (3)
1.0
2.0
Rapid medio (4)
1.5
3.5
Ultrarapid (5)
1.0
4.0
To identify the burners on your hob, refer to the drawings in point “8.3/8.4 Arrangement of
burners on hob “