Instructions for the installer
38
7
ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the
appliance from the electrical socket.
The hob has been inspected for
G20
(2H)
natural gas
at a pressure of
20 mbar. For functioning with other types of gas the nozzles must be
replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove
the top as described in the following paragraph.
7.1
Removing the separable control panel (models with
separable control panel)
1.
Remove the knobs and the knob guard tube “
A
” by pulling them
up;
2.
Use a crosshead screwdriver to remove the screws and the two
cylindrical supports “
B
”;
3.
Raise the left-hand side of the control panel slightly and shift it to
the right to remove it completely;
4.
In models with electric hotplate, the body of the pilot light has to be
removed to free the control panel;
7.2
Removing the hob (models with integrated control
panel)
1.
Remove the knobs, the griddles, the burner caps, the flame caps
and the two rear plugs;
2.
Remove the screws “
A
” which fix the burner supports;
Raise the hob, sliding it off the ignition plugs and/or the thermocouples
and the gas tap rods;