21
Regeneration frequency setup (models w ith softener)
(Default value:
H03
; m odify t he paramet er t o suit t he mains w at er hardness.
At first use, t he salt t ank has t o be filled. It is subsequent ly sufficient simply t o fill up w it h
regenerat ing salt w hen necessary.
Important:
During normal operat ion, t he dishw asher w ill perform a
number of w ashing cycles w hile regenerat ion is in
progress. During t his t ime (5-6 cycles) t he int ake w at er
w ill not be t reat ed, but t his w ill not affect t he w ashing
qualit y.
Ppm-
mg/ l
Hardness
(°dH
German
degrees)
Hardness
(°dF
French
degrees)
Setting level
Regenerat ion off
H00
150
8,5
15
H01
200
11
20
H02
300
17
30
H03
400
22,5
40
H04
500
28
50
H05
600
33,5
60
H06
Wit h values over 60°f an ext ernal w at er t reat ment device must be used and t he regenerat ion frequency
must be set on H00
.
Extra rinse
Rinsing is
10”
longer t han t he st andard in each w ashing
cycle.
On: enabled – OFF: disabled
.
"Clean w ater" cycle
Wit h t his opt ion clean w at er is used for
every w ashing
. At
each cycle, t he w ashing w at er is complet ely drained and it is
replaced w it h clean w at er from rinsing.
On: enabled – OFF: disabled
.
N.B.:
prolonged use of t his opt ion leads t o higher det ergent
and rinse aid consumpt ion.