Instruction for the installer
11
4
FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.
Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to
the appliance with the one corresponding to the new gas. This label is in the packet together with the
nozzles.
4.1
Regulation of the hob burner minimum level for natural gas
Light the burner and turn it to the minimum position . Extract the gas tap
knob and turn the adjustment screw at the side of the tap rod until the
correct minimum flame is achieved.
Replace the knob and check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the flame should not go out).
Repeat the operation on all the gas taps.
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and
to activate the safety device.
4.2
Regulation of the hob burner minimum level for LPG
For regulating the minimum with LPG, the screw at the side of the tap rod must be turned clockwise
all the way.
The bypass diameters for each individual burner are shown in paragraph “3.2 / 3.3 Burner and
nozzle characteristics table”. Once the regulation has been completed, replace the seal on the by-
passes using paint or similar materials.
4.3
Regulation of the oven burner minimum level
The oven thermostat is equipped with a by-pass to regulate the minimum level, which is visible
underneath the thermostat knob.
When the gas type is changed, the by-pass should be regulated as follows:
1.
Turn on the oven burner to maximum for 10/15 minutes with the door closed and without the
floor. Turn the knob to the minimum temperature, remove the knob and regulate using a flat
screwdriver.
2.
For LPG turn the by-pass screw clockwise as far as it will go. The by-pass diameter is shown in
the paragraph “3.2 / 3.3 Burner and nozzle characteristics table”.
3.
For natural gas, regulate the by-pass so that turning the thermostat knob from minimum to
maximum the flame remains stable and constant. Once the regulation has been completed,
replace the seal on the by-pass using paint or similar materials. Close the oven door and make
sure that the burner stays on minimum.
Summary of Contents for SCB80GX
Page 24: ...914772242 A...