31
Instructions for the installer
Operation at 220-240 V~:
use a
H05RR-F / H05RN-F three-core cable
(cable of 3 x 4 mm
2
).
Operation at 380-415V 2N~
: use a
H05RR-F / H05RN-F four-core cable (4 x
2.5 mm
2
).
Operation at 380-415V3N~
: use a
H05RR-F / H05RN-F five-core cable (5 x
2.5 mm
2
).
The end to be connected to the
appliance must be an earth wire (yellow-
green) at least 20 mm longer.
WARNING: The values indicated above refer to the cross-section of
the internal conductor.
14.2 Positioning the oven
The oven is designed for mounting into any piece of furniture as long as it
is heat-resistant. Proceed according to the dimensions shown in Figures
1
,
2
and
3
. For installing under a work top, follow the dimensions given in
Figure
1
-
3
. For installing under a work top with combined cooking hobs,
ensure a minimum clearance from any side walls of at least 110 mm as
shown in Figure
1
. When installing in tall units, comply with the dimensions
shown in figure
1
-
2
, bearing in mind that the top/rear of the unit must have
an opening 80-90 mm deep. Tighten the 4 screws
A
inside the frame (fig.
1
). For installing beneath a countertop hob, allow for a rear and bottom
clearance as shown in Figure
1
(ref.
B
). See the relevant instructions for
fitting and securing the hob.