14. INSTALLING THE APPLIANCE
14.1 Electrical connection
The I.D. plate with technical data, serial number and brand name is
positioned visibly on the oven door frame.
The plate must not be removed.
The appliance must be electrically grounded in compliance with the
electrical system safety regulations.
If a fixed connection is being used it is necessary to fit the power line with
an omnipolar circuit breaker with a contact opening gap equal to or greater
than
3 mm
, in an easily accessible position close to the appliance.
If a plug and socket connection are being used make sure that the plug
and socket are compatible. Avoid use of adapters and shunts as these
could cause overheating and risk of burns.
14.1.1 Ovens with hob controls
On ovens with hob controls
the power supply cable is not supplied
. Use
a H05RR-F or H05RN-F rubber cable and when positioning it ensure that
it does not touch the metal parts of the appliance's external casing.
To access the terminal board, remove the appliance's back cover by
unscrewing the relative screws. If necessary, change the positions of the
jumpers on the terminal board as shown, then connect the wires, making
sure that the earth wire is at least 20 mm longer. Fix the power supply
cable to the appliance using the cable clamp provided.