![Smeg S9GMXU9 Manual Download Page 17](http://html1.mh-extra.com/html/smeg/s9gmxu9/s9gmxu9_manual_1303685017.webp)
Installation
19
EN
The appliance should be installed in rooms
that have a permanent air supply in
accordance with the standards in force. The
room where the appliance is installed must
have enough air flow for the regular
combustion of gas and the necessary air
change in the room itself. The air vents,
protected by grilles, must be the right size to
comply with current regulations and
positioned so that no part of them is
obstructed, not even partially.
The room must be kept adequately
ventilated in order to eliminate the heat and
humidity produced by cooking: in
particular, after prolonged use, you are
recommended to open a window or to
increase the speed of any fans.
Gas connection
Connect the adapter
C
(ISO 228/1 -
½ NPT) to the gas inlet of the appliance
A
being sure to insert the supplied gasket
B
.
Apply a suitable sealing substance (such as
Teflon tape) between pressure regulator
D
and adapter
C
.
Connect the pressure regulator
D
to the
adapter
C
put on in the previous step (the
arrow on the back of the regulator points
towards the gas inlet of the appliance).
Apply a suitable sealing substance (such as
Teflon tape) between pressure regulator
D
and adapter
E
(½ NPT - ½ NPT) (not
supplied).
Connect the adapter
E
to the pressure
regulator
D
.
WARNING
: The tightening torque
of adapter (C / E) must not be
greater than 36 ozf - 10 Nm.