background image

 

 

Instructions for the installer

 

 

30

 

 

 

3.2

 

Burner and nozzle characteristics table 

 
Burner 

Rated 

heating 

capacity 

(kW) 

 

LPG – G30/G31

  30/37 mbar

 

 

 

Nozzle 

diameter 

1/100 mm 

By-pass 

mm 

1/100 

Reduced 

flow rate 

(W) 

Flow rate 

g/h G30 

Flow rate 

g/h G31 

Auxiliary (1) 

1.05 

50 

27 (*) 

28 (**)

350 

76 

75 

Semi rapid (2) 

1.8 

65 

33 (*) 

32 (**)

450 

130 

128 

Rapid (3) 

2.3 

75 

43 (*) 

42 (**)

800 

166 

164 

Ultra rapid (4) 

3.5 

94 

63 

1.6 

253 

250 

*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in 
point “4.1 Regulation of minimum for natural gas”. 

 

 
Burner 

Rated 

heating 

capacity 

(kW) 

 

Natural gas – G20

  20 mbar

 

 

 

Nozzle diameter 

1/100 mm 

Reduced flow rate 

(W) 

Auxiliary (1) 

1.05 

72 

350 

Semi rapid (2) 

1.8 

97 

450 

Rapid (3) 

2.3 

103 

800 

Ultra rapid (4) 

3.5 

133 

1500 

 

 
Burner 
 

Rated  

heating 

capacity  

(kW) 

 

Town gas – G110

  8 mbar

 

 

 

Nozzle diameter 

1/100 mm 

Reduced flow rate 

(W) 

Auxiliary (1) 

1.05 

145 

350 

Semi rapid (2) 

1.8 

185 

450 

Rapid (3) 

2.3 

220 

800 

Ultra rapid (4) 

3.3 

290 

1500 

 

 

Values for town gas are based on category III 1a2H3+ appliances. 

 

 

 

3.3

 

Arrangement of burners on cooking hob 

  

 

BURNERS 

 

Auxiliary   

Semi rapid  

3 Rapid 
4 Ultra 

rapid 

Summary of Contents for PGF95K

Page 1: ...AINTENANCE ___________________________ 34 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these...

Page 2: ...VE THE PACKAGING MATERIALS UNATTENDED IN THE HOME ENVIRONMENT SEPARATE THE DIFFERENT WASTE MATERIALS FROM THE PACKAGING AND DELIVER THEM TO THE NEAREST COLLECTION CENTRE FOR RECYCLABLE WASTE REGULATIO...

Page 3: ...E APPLIANCE IS DESIGNED FOR USE BY ADULTS DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQ...

Page 4: ...he 1 figure to avoid damage from overheating Make sure there is a minimum of 750 mm between the gas rings and any shelf that may be installed directly above them Carefully position the gasket provided...

Page 5: ...there is a minimum of 750 mm Fig 1 between the gas rings and any shelf that may be installed directly above them This type of appliance also requires a cut 3 mm deep in the work top with the dimension...

Page 6: ...illed surface Important Other types of installation will only be possible under the manufacturer s supervision Overall dimensions location of gas and electrical connection points all measures in mm Ca...

Page 7: ...ee detail B fig 5 The following figures show how to use the brackets IMPORTANT when installing the appliance above a cupboard a dividing shelf as shown above must be installed If installed above an un...

Page 8: ...ar the appliance Do not use reducers adapters or shunts If the power cable is to be replaced the wire section on the new cable must not be less than 0 75 mm2 3 x 0 75 cable bearing in mind that the en...

Page 9: ...be blocked in any way The room must be suitably ventilated to avoid overheating or excess humidity produced by cooking after any prolonged use a window should be opened or the speed of any fans should...

Page 10: ...s must not provoke stress of any kind on the appliance Connection may be made by using biconicaladapter D with insertion of gasket C supplied Connection with flexible steel pipe use only flexible stai...

Page 11: ...d and the minimum flame adjusted on the gas taps To change the nozzles proceed as described below 3 1 Replacement of nozzles on the hob 1 Remove the grids and all the caps and flame spreader crowns 2...

Page 12: ...valves marked and shown in point 4 1 Regulation of minimum for natural gas Burner Rated heating capacity kW Natural gas G20 20 mbar Nozzle diameter 1 100 mm Reduced flow rate W Auxiliary 1 1 05 72 350...

Page 13: ...urn the regulation screw inside or next to the gas tap pin depending on the model until you get a suitable minimum flame Replace the knob and check burner flame stability when you turn the knob quickl...

Page 14: ...each knob indicates the relative burner The device is fitted with electronic ignition Simply press and turn the knob counter clockwise to the high flame symbol until the burner is ignited In models w...

Page 15: ...r the flame so that it does not boil over To avoid burns or damage to the worktop all receptacles or griddle plates must be placed within the perimeter of the cooking hob When using fats or oils be ex...

Page 16: ...llic scourers or sharp scrapers be used they will damage the surface Use normal non abrasive products for steel and a wooden or plastic tool if necessary Rinse thoroughly and dry with a soft cloth or...

Reviews: