Instructions for the installer
EN
43
12. ADAPTATION TO DIFFERENT TYPES OF GAS
BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER
SUPPLY TO THE APPLIANCE.
Appliance set for gas:
NG – 1.0 kPa
(see label on product)
In case of operation with other types of gas, the burner nozzles must be changed
and the minimum flame adjusted on the gas taps.
To change the nozzles, proceed as described in the following paragraphs.
12.1 Replacing the hob nozzles
1
Remove the pan stands, and
remove all burner caps and
flame-spreader crowns to access
the burner casings.
2
Unscrew the nozzles using a 7
mm socket wrench.
3
Replace the burner nozzles
according to the type of gas to be
used (see 12.2 Burner and
nozzle characteristics table).
4
Replace the burners in the correct position.
12.2 Burner and nozzle characteristics table
For burner arrangement, see “Instructions for the user - 6.4 Cookware diameters”.
Burner
NG – 1.0 kPa
Nominal gas
Consumption (MJ/h)
Turn-down gas
consumption (MJ/h)
Injector
(mm)
1
Auxiliary
3.9
1.3
0.90
2
Semi-rapid
7.5
1.6
1.20
3
Rapid
12
2.7
1.55
4
WOK
15.2
5.7
0.80 + 1.65
5
Fish pan
7.8
2.9
1.26
Burner
ULPG – 2.75 kPa
Nominal gas
Consumption (MJ/h)
Turn-down gas
consumption (MJ/h)
Injector
(mm)
1
Auxiliary
3.9
1.3
0.54
2
Semi-rapid
6.3
1.6
0.68
3
Rapid
10.8
2.7
0.88
4
WOK
15.2
5.7
0.46 + 0.94
5
Fish pan
6.8
2.9
0.72