EN
9
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using a
rigid 6” duct. (not supplied)
• Install the damper 10a ø 6”.
• Fix the duct in position using sufficient pipe clamps.
Electrical connection
• Remove the cover from the Field Wiring Compartment
with a phillips screwdriver.
• Feed the Power Supply Cable through the electrical
knockout. Connect the Power Supply Cable to the ran-
ge- hood cable. Attach the Power Supply Cable grounding
lead to the green screw provided. Attach the White lead of
the power supply to the White lead of the rangehood with
a twist-on type wire connector. Attach the Black lead of the
power supply to the Black lead of the rangehood with a
twist-on type wire connector.
• Replace the cover.
EN
1
12
Electrical connection
• Remove the cover from the Field Wiring Compartment with a phillips
screwdriver.
• Feed the Power Supply Cable through the electrical knockout. Connect
the Power Supply Cable to the range- hood cable. Attach the Power
Supply Cable grounding lead to the green screw provided. Attach the
White lead of the power supply to the White lead of the rangehood with a
twist-on type wire connector. Attach the Black lead of the power supply
to the Black lead of the rangehood with a twist-on type wire connector.
• Replace the cover.