9
5.3 Air connection systems
5.3.1 DUCTING version
The hood is supplied in the
filter
version. Follow the instructions below to set-up the hood in the
ducting
version. Fig. 5.3.1
–
1)
Unscrew 2 screws on the casing
–
2)
Remove the casing
–
3) Remove the
activated carbon filter. Fig. 5.3.2
–
4)
Insert 2 half valves into the motor
inlet
–
5) Replace the casing over the
motor
–
6) Screw the 2 screws back
onto the casing. Fig. 5.3.3
–
7) Connect
the motor to the fumes outlet with a
conduit having an internal diameter of
150 mm. Test by turning on the hood
and pressing the maximum speed
button
. Fig. 5.3.4
–
8) Position the
flue above the hood
–
9) Secure the
casing with two screws. After 100
hours of hood operation, the lights of
buttons
,
and
will flash
until the reset is complete. In the
ducting configuration, because there
is no activated carbon filter, you
simply have to reset the controls, as indicated in
the “Hood operation” section.
5.3.2 FILTER version
The hood is supplied in the
filter
version. After 100 hours of hood operation, the lights of buttons
,
and
will flash to indicate that the active carbon filter should be replaced. Contact the
nearest authorized SMEG service centre to purchase a replacement activated carbon filter: model
FLT6
. Follow the instructions below to replace it. Fig. 5.3.1 - 1) Unscrew the 2 screws from the casing
–
2) Remove the casing
–
3) Replace the activated carbon filter
–
2) Replace the casing over the motor
–
1) Screw the 2 screws back onto the casing. Test by turning on the hood and pressing the maximum
speed button
. The old filter should be disposed of in accordance with the current regulations
in the country of installation.
Instructions for the installer
EN
Summary of Contents for K43X
Page 1: ...1 EXTRACTOR HOOD K43X Instructions booklet ...
Page 2: ...2 ...
Page 19: ...19 ...
Page 20: ...20 1701073 ...