Instructions for the installer
24
8.2
Adjustment for ULPG
Loosen screw
A
and push support
B
all the way. Using a a double head, remove
nozzle
C
and replace it with the appropriate nozzle, following the instructions in
the tables for the type of gas to be used. The nozzle tightening torque must be
no more than 3 Nm. Reposition support
B
so that nozzle
C
is covered perfectly.
Move the Venturi tube
D
to adjust the air flow until distance “X” is reached as
indicated in the table in paragraph “8.4 Primary air adjustment” and then secure
the tube by means of screw
A
. After the adjustments have been carried out,
restore the seals with sealing wax or equivalent material.
Burner
ULPG – 2.75 kPa
Nominal gas
Consumption (MJ/h)
Injector
(mm)
Auxiliary (1)
4.8
0.60
Semi rapid (2)
6.0
0.68
Reduced rapid (3)
10.0
0.85
Wok (4)
14.0
0.98
Wok double control (5)
Internal
4.0
0.48
External
12.5
0.95
8.3
Adjustment for natural gas
The hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. To reset the
appliance for operation with this type of gas, carry out the same steps as
described in “8.2 Adjustment for ULPG”, but select the nozzles and adjust the
primary air for natural gas as indicated in the table below and in "8.4 Primary air
adjustment”. After the adjustments have been carried out, restore the seals with
sealing wax or equivalent material.