3
2 Technical
data
Supply voltage
V 400V
3N
~
- convertible to single-phase version
V 230V-1N
~
Frequency
Hz 50
Max. power absorption at 400V 3N ~
kW
4,8
Max. power absorption at 230V 1N ~ (double heating)
kW
3,3
Max. power absorption at 230V 1N ~ (single heating)
kW
1,8
Boiler heating element power at 400V 3N ~
kW
4,5
Boiler heating element power at 230V 1N ~
kW
1,5
Tank heating element power
kW 0,8
Water intake pressure
kPa (bar)
100-600 (1 ÷ 6)
Water intake temperature
°C
15°C – 60°C
Water hardness (models with softener)
°dF 15°dF-60°dF
Rinse cycle water consumption
l 2,3
Boiler capacity
l 4
Tank capacity
l 7
Standard cycle duration with intake water at 50°C
s 90/150/240
Noise level
dB(A) <
60
Degree of protection
IPX 4
Net weight
kg 44/47
Power supply cable type
◄
HAR
►
H07RN-F
Fuse
A
4
400V 3N ~
230V 1N ~
C S C S
C
= Power Supply Cable.
S
= Master Switch
1,8 kW
---
…
3x2
,5
16A
1P+N
3,3 Kw
…
3x2
,5
16A
1P+N
With two heating branches connected in parallel.
4,8 kW
5x2,5
16A
3P+N
--- ---